E2. "ANSI_cd"
~123
Start of header
{
(left bracket)
~044
Parameter
,
(comma)
separator
~034
Quoted strings
"
(quotes)
~124
Field separator
p
(pipe sign)
~125
End of header
}
(right bracket)
~126
Data escape
~~
(double tilde)
character (optional)
def. ch.
Immediate command character (optional).
Up to any 3 characters in the 0 to 255 decimal
range. The character must be defined before this
command can be used. The caret (^) is
normally used.
NOTE:
"ANSI_cd" includes seven separate parameters.
The first five parameters are required. The other
parameters are optional.
E3. "string 1"
Terminator for status requests and ENQ requests. Up to
any 3 characters in the 0 to 255 decimal range. The
default is "013". Sending "" disables this sequence.
E4. "string 2"
Terminator for job requests and data uploads. Up to any 3
characters in the 0 to 255 decimal range. The default is
none. Sending "" disables this sequence.
The defaults listed above are the defaults for all printers.
After you change these parameters, all packets, including any
future configuration packets, must use the new control
characters. Monarch recommends using the tilde and ASCII
character code sequence when sending this packet multiple
times. Also, set the packet delimiters to characters within the
21 hex to 7E hex range.
You must send the control characters packet to enable the
immediate commands. An immediate command executes
immediately, even if it is embedded within quotation marks,
and all data following the command in the string is ignored.
Example
{
I
,E,"~123~063~034~124~125~126~094"
p
}
Changes the parameter separator character from
,
to
?
. The
other control characters remain unchanged. It also enables
the immediate commands by defining the ^ symbol as the
command identifier.
MPCLII Packet Reference Manual
3-12
Summary of Contents for Monarch 1460
Page 14: ...MPCLII Packet ReferenceManual 1 6 ...
Page 76: ...MPCLII Packet ReferenceManual 4 24 ...
Page 94: ...MPCLII Packet ReferenceManual 5 18 ...
Page 116: ...MPCLII Packet ReferenceManual 7 14 ...
Page 154: ...MPCLII Packet ReferenceManual 10 8 ...
Page 162: ...MPCLII Packet ReferenceManual A 8 ...
Page 166: ...MPCLII Packet ReferenceManual A 12 ...
Page 168: ...Bold Font OCRA like Font Standard Font Reduced Font MPCLII Packet ReferenceManual B 2 ...
Page 169: ...CG Triumvirate Bold Font CG Triumvirate Font Appendix B Fonts B 3 ...
Page 183: ...Code Page 437 Appendix C Symbol Sets CodePages C 7 ...
Page 184: ...Code Page 850 MPCLII Packet ReferenceManual C 8 ...
Page 188: ...MPCLII Packet ReferenceManual C 12 ...
Page 216: ......