Error
Code
Description
575
The graphic included in your format could not be
found.
600
Imaging error because the batch was refused.
Resend the batch. If the error persists, call
Technical Support.
601
An error occurred while the batch was imaging.
Resend the batch. If the error persists, call
Technical Support.
602
The batch was not found during imaging. Resend
the batch. If the error persists, call Technical
Support.
611
Font, bar code or density is invalid. The font, bar
code or density in the batch does not fit the format.
612
The data in this line of the batch is either missing or
does not match the format.
613
Reference point off tag.
614
Portion of field off tag. There may be an invalid
character in the packet. Make sure you did not
enter
O
for
0
.
615
Bar code width is greater than 16 inches or the
number of keywords for your PDF 417 bar code
exceeds
928
. Decrease the density or shorten the
amount of data to print the bar code.
616
A bad dot falls on a bar code and the dot cannot be
shifted. Call Technical Support.
618
Magnification must be
1
to
7
or
4
to
90
(point size)
for the scalable font. The range with the scalable
font on the 9490 printer is
4
to
200
points.
MPCLII Packet Reference Manual
9-16
Summary of Contents for Monarch 1460
Page 14: ...MPCLII Packet ReferenceManual 1 6 ...
Page 76: ...MPCLII Packet ReferenceManual 4 24 ...
Page 94: ...MPCLII Packet ReferenceManual 5 18 ...
Page 116: ...MPCLII Packet ReferenceManual 7 14 ...
Page 154: ...MPCLII Packet ReferenceManual 10 8 ...
Page 162: ...MPCLII Packet ReferenceManual A 8 ...
Page 166: ...MPCLII Packet ReferenceManual A 12 ...
Page 168: ...Bold Font OCRA like Font Standard Font Reduced Font MPCLII Packet ReferenceManual B 2 ...
Page 169: ...CG Triumvirate Bold Font CG Triumvirate Font Appendix B Fonts B 3 ...
Page 183: ...Code Page 437 Appendix C Symbol Sets CodePages C 7 ...
Page 184: ...Code Page 850 MPCLII Packet ReferenceManual C 8 ...
Page 188: ...MPCLII Packet ReferenceManual C 12 ...
Page 216: ......