Connections to the motor
49
Unit
hardware
Connector
assignment / cable
Technical data
Configuration
Positioning and
control functions
Optimization
functions
Interfaces
Accessories /
options
Status
Parameter
Error list
MOK21 (max. 18,9A)
CY-JZ 7x2,5
No. 102-508902
PE
Br. -24V
Br. +24V
W
V
U
PE
Br-
Br+
W
V
U
MOK21
30 mm
30 mm
30 mm
110 mm
75 mm
110 mm
75 mm
35 mm
15 mm
10 mm
190 mm
20 mm
170 mm
15 mm
10 mm
sw1/sw
sw2/br
sw3/bl
sw4/rt
sw5/gr
sw6
gn/ge
standard/hochflex
black1/black
black2/
brown
black3/blue
black4/red
black5/
green
black6
green-yellow
standard/highflex
Version in high-flex: MOK14 (same layout)
MOK11 (max. 32.3A) in high-flex (same layout to MOK21, however in 6 mm
2
)
MOK46 (max. 47.3A) in high-flex (same layout to MOK21, however in 10mm
2
)
Packaging
Packaging of device
Material:
6 x crimping sleeves.
6 cm shrink-fit hose.
Procedure:
•
Strip 110 mm sheathing off cable.
•
Cut sheath down to approx. 35 mm, loosen,
•
fold back over outer cover (approx. 75 mm) and stick with insulating tape.
•
Shorten sw1,sw2,sw3,sw4,sw5 ca. 15 mm (gn/ge approx. 15 mm longer) cut down sw6.
•
Attach 2 x approx. 30 mm shrink-fit hose (sticky).
•
Strip 10 mm of insulation off ends of wires and secure with crimping sleeves 2.5.
Packaging of motor in accordance with manufacturer's specification
•
Strip 190 mm sheathing of cable.
•
Cut sheath down to approx. 170 mm, stick remaining 20 mm with insulating tape.
•
Shorten sw1,sw2,sw3,sw4,sw5 by approx. 15 mm (gn/ge approx. 15 mm longer) cut down sw6.
•
Strip 10 mm of insulation of ends of wires and secure with crimping sleeves 2.5.
Shrink-fit hose