Accessories
EAM5/01: DC feed for COMPAX-M
189
Unit
hardware
Connector
assignment / cable
Technical data
Configuration
Positioning and
control functions
Optimization
functions
Interfaces
Accessories /
options
Status
Parameter
Error list
9.7.3 EAM5/01: DC feed for COMPAX-M
The power supply is normally over a central mains module; NMD10 or NMD20.
With the component EAM5/01, available as an accessory, DC voltage can be
supplied: the component contains the connections of the mains module.
Input voltage range
100V DC – 650V DC.
The DC intermediate circuit must be limited to 750V in braking mode.
Power voltage is connected directly to COMPAX-M X2
HAUSER
C O M P A X -M
DIGITAL
S ta tu s
N u m ber
X6
X8
X10
-
+
E nt er
R eady
E rr or
R S232
Inp u t
O utp u t
T est
C on tro l
X9
X11
Value
DIGITAL
S ta tu s
N u m ber
X6
X8
X10
-
+
E nt er
R eady
E rr or
R S232
Inp u t
O utp u t
T est
C on tro l
X9
X11
Value
COMPAX-M
Motion & Control
COMPAX-M
Motion & Control
DIGITAL
S ta tu s
N u m ber
X6
X8
X10
-
+
E nt er
R eady
E rr or
R S232
Inp u t
O utp u t
T est
C on tro l
X9
X11
Value
U V W PE Brake
PE + -
X5
X1
X2
X3
X4
24V DC
0V
PE
+LS
-LS
COMPAX-M
EAM5/01 X4
Design of EAM5/01:
X6
X7
X3
X4
X8
F21
78
.0 m
m
68.0 mm
Note
♦
UMK housing from Phoenix
♦
to be attached to top hat rail of various sizes
♦
without mating connector approx. 4.5 cm deep
Terminal assignment
The component contains the connections of the mains module.
EAM5/01 X6 = mains module X6: input bus systems
EAM5/01 X7 = mains module X7: output bus systems
EAM5/01 X3 = mains module X3: 24V DC supply
X3/3: PE
X3/2: 24V DC
X3/1: 0V
Supply voltage
for functions of
X8.