Chapter 3 Installation 95
AC Power Connection
After securely installing all other cables on the ACR9000 or ACR9030
controller, connect the device to an external 120/240 VAC mains power
source. For more information on power requirements and the AC power
connector, see Electrical Specifications on page 26.
DC Power Connection
The ACR9040 must be powered by a non-isolated 24 VDC power supply.
Parker’s PS-60W is an isolating DC power supply which can be converted to
non-isolated by connecting an 18 AWG jumper between the DC return and
Earth ground.
After securely installing all other cables on the ACR9040, connect the device
to the non-isolated 24 VDC power supply. See Figure 31. For more
information on power requirements and the DC power connector, see
Electrical Specifications on page 26, and DC Power Connector (ACR9040)
on page 27.
Warning —
Damage to the ACR9040 will result if the 24 Volt supply used on
the DC Power connection is shared with an inductive load (such as brakes,
solenoids, contactors, or relays).
Figure 31 ACR9040 DC Power Connection