![Parker ACR9000 Installation Manual Download Page 50](http://html1.mh-extra.com/html/parker/acr9000/acr9000_installation-manual_3855262050.webp)
Parker
Hannifin
GP Trigger Input/Output Electrical/Timing Characteristics
GP Inputs 0
−
11, 12
−
23
Description
Min
Max
Units
Turn-on time
--
1
ms
Turn-off time
--
1
ms
Guaranteed on voltage
21
--
VDC
Guaranteed off voltage
--
3
VDC
Maximum forward voltage
--
30
VDC
Maximum reverse voltage
−
30
--
VDC
Forward current
6.3
15
mA
Note:
All parameters are at the connector pin.
Table 24 GP Inputs 0
−
11 & 12
−
23 Connector Electrical/Timing Characteristics
GP Inputs 24
−
31, 72
−
79
Description
Min
Max
Units
Turn-on time
--
400
ns
Turn-off time
--
400
ns
Guaranteed on voltage
21
--
VDC
Guaranteed off voltage
--
3
VDC
Maximum forward voltage
--
30
VDC
Maximum reverse voltage
−
30
--
VDC
Forward current
6.3
15
mA
Note:
All parameters are at the connector pin.
Propagation delay due to filtering and isolation is ~400 ns, or encoder capture
resolution of +/
−
5 counts at 10 MHz.
Table 25 Trigger Inputs 24
−
31, 72
−
79 Connector Electrical/Timing Characteristics
50 ACR9000 Series Hardware Installation Guide