Parker
Hannifin
108 ACR9000 Series Hardware Installation Guide
Command Language Reference (Online Help System in the ACR-
View software).
Although a stepper does not require tuning, you must set
PGAIN
equal to 0.00244141 and all other gains equal to 0.
3. If the drive is enabled, but you cannot command motion, check and
remedy the following condition.
If you have attached the axis of motion to a master axis with one or
more slave axes faulted, motion stops on all slave axes until you
clear the flags. For more information on the
ATTACH
command, Kill
All Motion Request axis flag and Kill All Motion master flag, refer to
the ACR Command Language Reference (Online Help System in
the ACR-View software).
4. If the drive holds torque when you disable the axis, and loses torque
when you enable the axis, check the value of the Drive Enable Output
Shuts Down Drive flag. Some drives implement reverse functionality of
the disable and enable settings.