![Parker ACR9000 Installation Manual Download Page 92](http://html1.mh-extra.com/html/parker/acr9000/acr9000_installation-manual_3855262092.webp)
Parker
Hannifin
ACR90x0
Node Number
Parameter
Default
ID Value
0
33024
1
1
33040
0
2
33056
0
3
33072
0
Example
Suppose you are installing a three node network. To set the
number of nodes in the network, the following parameter is
set:
P32770=3
Next, the hardware addresses are assigned. The first node
requires no configuration—the factory default hardware ID is
set to 1, and the ACR90x0 is factory configured to recognize
hardware ID 1. The hardware of the second and third nodes
are configured, then the following parameters are set:
P33040=2
P33056=3
5. To start the network, send the
SET11265
command to set bit
11265.
The controller and I/O nodes should have steady green LEDs
6. Send the
ESAVE
command.
Ethernet Cable Specification
Cable....................................................... RJ-45 Ethernet, unshielded CAT 5E
Ethernet Connection
The Ethernet port is located on the front panel of the ACR90x0. (For
specifications, see Ethernet Connector on page 60.)
Before connecting to an Ethernet port, you must configure the ACR90x0 to
use an IP address and subnet mask that is valid for your network. The
factory assigns an IP address of 192.168.10.40 and a subnet mask of
255.255.255.0 to each controller. Before adding the controller to your
network, assign it an IP address and subnet mask appropriate for your
network.
Important!
Talk with your Network Administrators before assigning an IP address or
subnet mask to a controller. They can provide you with an available IP
address, as well as which subnet mask is appropriate for your particular
network configuration.
92 ACR9000 Series Hardware Installation Guide
www.comoso.com
Summary of Contents for ACR9000