B. Standards Compliance for SNMP Traps
8776-A2-GB20-40
February 2001
B-5
The tests that affect the enterpriseTestStart, enterpriseTestStop, and the
variable-bindings are different for each particular interface. Diagnostic tests are
only supported on the physical E1 network and user data port interfaces. The
specific tests and variable-bindings are described in the following table:
Interface
enterpriseTestStart/Stop
Variable-Bindings
Possible Cause
SDSL
Network
ifIndex (RFC 1573)
ifAdminStatus (RFC 1573)
ifOperStatus (RFC 1573)
ifType (RFC 1573)
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopLLB – Initiates a Local
Loopback.
– testLoopRLB – Initiates a
Remote Loopback.
– testSendMon511 – Initiates a
Send and Monitor 511 test.
– testSendLLBUp – Initiates an
LLB Up message to the remote
unit.
– testSendLLBDown – Initiates an
LLB Down message to the
remote unit.
enterpriseTest Start – Any one
of the following tests is active
on the interface:
– Line Loopback
– Repeater Loopback
– Remote Line Loopback
– Send and Monitor 511
enterpriseTest Stop – No tests
currently running on the
interface.
G.703
ifIndex (RFC 1573)
ifAdminStatus (RFC 1573)
ifOperStatus (RFC 1573)
ifTestType (RFC 1573)
The following objects control tests
in SNMP-managed devices:
– noTest – Stops the test in
progress.
– testLoopExternalDTE
Summary of Contents for Hotwire 8776
Page 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8776 A2 GB20 40...
Page 52: ...4 Monitoring the Unit 4 16 February 2001 8776 A2 GB20 40...
Page 62: ...5 Testing 5 10 February 2001 8776 A2 GB20 40...
Page 68: ...6 Messages and Troubleshooting 6 6 February 2001 8776 A2 GB20 40...
Page 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8776 A2 GB20 40...
Page 102: ...D Technical Specifications D 2 February 2001 8776 A2 GB20 40...