4. Monitoring the Unit
8776-A2-GB20-40
February 2001
4-3
Health and Status Messages
The following messages appear in the first column of the System and Test Status
screen. The highest priority Health and Status message also appears on all ATI
screens on the bottom right.
Table 4-1.
Health and Status Messages (1 of 2)
Message
What Message Indicates
What To Do
AIS at G.703, Pt
n
An Alarm Indication Signal
(AIS) is being received by the
G.703 interface.
1. Verify that the unit’s line
framing and line coding are
compatible.
2. Contact network provider.
Device Failed
yyyyyyyy
An internal error has been
detected by the operating
software.
yyyyyyyy indicates
the 8-digit hexadecimal
failure code.
1. Provide the 8-digit failure
code shown (
yyyyyyyy) to
your service representative.
2. Reset the unit to clear the
condition and message.
Download Failed
A firmware download was
interrupted.
Repeat the download.
EER at G.703, Pt
n
An EER (Excessive Error
Rate) condition has been
detected on the G.703
interface.
1. Verify that the network cable
is securely attached at both
ends.
2. Verify proper NTU and LTU
configuration.
3. Contact network provider.
EER at Net, Pt
n
An EER (Excessive Error
Rate) condition has been
detected on the network
interface at Port
n. The
condition is cleared when the
error rate falls below the
threshold value currently
configured.
1. Ignore condition if 511 test
active.
2. Contact network provider.
Fallback Rate,
Pt
n
The LTU, set to AutoRate
enable, synchronized at a
lower rate when the line was
restored after an LOS.
Reset AutoRate.
AutoRate is designed to find the
best rate possible for your DSL
loop conditions. After the DSL
loop is up units should be run in
fixed rate.
LOF at G.703, Pt
n
An LOF (Loss Of Frame)
condition has been detected
on the G.703 interface.
1. Verify that the network cable
is securely attached at both
ends.
2. Contact network provider.
3. Verify that the units line
framing and line coding are
compatible.
Summary of Contents for Hotwire 8776
Page 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8776 A2 GB20 40...
Page 52: ...4 Monitoring the Unit 4 16 February 2001 8776 A2 GB20 40...
Page 62: ...5 Testing 5 10 February 2001 8776 A2 GB20 40...
Page 68: ...6 Messages and Troubleshooting 6 6 February 2001 8776 A2 GB20 40...
Page 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8776 A2 GB20 40...
Page 102: ...D Technical Specifications D 2 February 2001 8776 A2 GB20 40...