A. Configuration Options
8776-A2-GB20-40
February 2001
A-9
Table A-4.
System Options
DSL Mode
Possible Settings: LTU, NTU
Default Setting: LTU
Controls whether the unit is configured as a control unit or tributary unit.
LTU – The unit is configured as a control unit (Line Termination Unit).
NTU – The unit is configured as a tributary unit (Network Termination Unit). This unit will
request its IP address from the LTU during establishment of the PPP link.
NOTE: Changing this option will reset the card.
Test Timeout
Possible Settings: Enable, Disable
Default Setting: Enable
Allows tests to end automatically. The feature should be enabled when the unit is remotely
managed, so that control can be regained after a test is accidentally executed.
Enable – Loopback and pattern tests end when test duration is reached.
Disable – Tests run until manually terminated from the Network Tests screen or remotely
(network initiated tests). Refer to
Running Network Tests
in Chapter 5,
Testing.
Test Duration (min)
Possible Settings: 1 – 120
Default Setting: 10
Number of minutes for a test to be active before automatically ending.
Test Duration (min) option appears when Test Timeout is enabled.
1 – 120 – Amount of time in minutes for a test to run before terminating.
G.703 Line Termination
Possible Settings: 75 ohms, 120 ohms
Default Setting: 120 ohms
Specifies the impedance of the G.703 interface
75 ohms – The G.703 interface impedance is 75 ohms unbalanced.
120 ohms – The G.703 interface impedance is 120 ohms balanced.
Summary of Contents for Hotwire 8776
Page 24: ...2 Using the Asynchronous Terminal Interface 2 10 February 2001 8776 A2 GB20 40...
Page 52: ...4 Monitoring the Unit 4 16 February 2001 8776 A2 GB20 40...
Page 62: ...5 Testing 5 10 February 2001 8776 A2 GB20 40...
Page 68: ...6 Messages and Troubleshooting 6 6 February 2001 8776 A2 GB20 40...
Page 98: ...B Standards Compliance for SNMP Traps B 6 February 2001 8776 A2 GB20 40...
Page 102: ...D Technical Specifications D 2 February 2001 8776 A2 GB20 40...