![Paradyne 1813 User Manual Download Page 53](http://html.mh-extra.com/html/paradyne/1813/1813_user-manual_753811053.webp)
Command Line Interface User’s Guide
5.2.5
elink
elink <interface> -o [[auto] | [10 | 100 | auto_speed ] | [half | full | auto_duplex]
The
elink
command configures the speed and/or duplex of the Ethernet interface. The default
setting is auto for auto negotiation. With auto negotiation, both the speed and duplex are
configured based upon what the link is connected to. It is also possible to configure the duplex,
say half and full, and specify auto_speed so that only the speed is auto negotiated. Similarly for
auto_duplex.
COMMAND DESCRIPTION
<interface>
The name of the Ethernet interface. This is eth0.
Auto
This specifies that both the speed and duplex are auto negotiated.
10
This specifies that the speed is set to 10M bits per second.
100
This specifies that the speed is set to 100M bits per second.
auto_speed
This specifies that the speed is auto negotiated.
half
This specifies half duplex
full
This specifies full duplex
auto_duplex
This specifies that the duplex is auto negotiated.
EXAMPLE
[1234 @ ethernet]$ elink eth0 -o 10 half
This command sets the Ethernet to a speed of 10Mbps half duplex.
[1234 @ ethernet]$ elink eth0 -o auto_speed full
The speed will be auto negotiated and the link will use full
1800-A2-GB20-00
53