25
6.6.5 Shutdown Codes
Streamline - Sections 48 to 53
?
Hexa Programming - Addresses
448-471
If the Auto Zone Shutdown (see section 7.11.1) feature is enabled, the control panel will send
the programmed event code to the Central Station identifying which zones were shutdown.
6.6.6 Tamper/Trouble Codes
Streamline - Sections 54 to 56
?
Hexa Programming - Addresses
472-483
If the
Tamper/Wire Fault Recognition Options
are disabled (see section 10.7), the control
panel will never transmit these event codes. Otherwise, whenever a tamper occurs on a
zone, the control panel will send the programmed Event Code to the Central Station. With
Advanced Technology Zoning (ATZ)
enabled (see section 7.2) each Tamper Code address
will represent two zones (e.g. Tamper 1 = zones 1 & 2, Tamper 2 = zones 3 & 4, etc.). The
control panel will send the programmed Event Code when a tamper occurs on either zone.
6.6.7 Trouble/Restore Codes
Streamline - Sections 60 to 63
?
Hexa Programming - Addresses
496-511
Each of the these addresses represent a specific trouble or restore condition. The control
panel will report the appropriate event code to the central station when one of the following
conditions occurs or after the condition has returned to normal.
496 -
Max. Auxiliary Current:
the current draw from auxiliary is
?
1.1A.
504 -
Max. Auxiliary Current Restore
497 -
Bell Disconnect/Max. Bell Current:
Bell is disconnected or Bell current is
?
3A.
505 -
Bell Disconnect Restore:
No restore code for bell current.
498
-
Battery Disconnect/Low Voltage: Battery disconnected or battery voltage
?
10.5V.
506 -
Battery Disconnect/Low Voltage Restore
499 -
Power Failure:
Voltage on AC input is
?
12.5V.
507 -
Power Failure Restore
500 -
Fire Loop Trouble:
A tamper occurs on a fire zone (Zone 3/24hr.).
508 -
Fire Loop Trouble Restore
501 -
Timer Loss:
The control panel detects a loss in the panel timer.
509 -
Timer Programmed
502 to 503 -
Reserved for Future Use
510 -
All Tamper/Trouble Codes
(see section 6.6.6) have returned to "normal".
511 -
TLM Trouble Restore:
Telephone line has restored after the TLM (see section 10.1)
has detected the loss of a telephone line.
6.6.8 Special Codes
Streamline - Sections 64 to 67
?
Hexa Programming - Addresses
512-527
Each address represents a special condition in the system. When one of these special
conditions occur, the control panel will report the event code associated with the address.
512 -
Test Report:
The test report has been activated either manually (see section 6.8) or
automatically (see section 6.7).
513 -
Panic 1:
Keys [1] and [3] or a PS1 is pressed to activate a Panic 1 alarm
514 -
Panic 2:
Keys [4] and [6] are pressed to activate a Panic 2 alarm
515 -
Panic 3:
Keys [7] and [9] are pressed to activate a Panic 3 alarm
For more information on Keypad Panic Options see section 10.4
516 -
Late To Close:
"
Timed
"
Auto Arming
is enabled (see section 8.1) and the system has
not
automatically armed itself at the specified time.
517 -
No Movement:
"
No Movement
"
Auto Arming
is enabled (see section 8.2) and no
movement has occurred for the designated amount of time.
Event Reporting