37
8.7
Exit Delay
Decimal Programming
?
Address 049
Default: 60 seconds
Exit Delay applies to all zones. This option determines how much time the user has to leave the
protected area before the system arms after entering a valid access code. You can program the
Exit Delay from 001 to 255 sec.
[
ENTER
]
+
Installer Code
+
[10] [4] [9]
+
3 digit decimal value (001-255)
+
[
ENTER
]
8.8
Beep on Exit delay
Feature Select Programming
?
Address 088, key [12]
Default: Disabled
With this feature enabled, the keypad will emit an intermittent "beep" during the programmed exit
delay period (except when in "stay" arming). The frequency of intermittent beeps increases during
the last 10 seconds of the exit delay period. For more information on
Exit Delay
refer to section 8.7.
Key [12] "Off": Beep on Exit Delay Disabled
Key [12] "On": Beep on Exit Delay Enabled
[
ENTER
]
+
Installer Code
+
[10] [8] [8]
+
[12]
On/Off
+
[
ENTER
]
8.9
Alarm Transmission Delay
Decimal Programming
?
Address 059
This time limit, set between 5 and 63 seconds, is the delay period before reporting an alarm to the
central station after an alarm condition. During this period, disarming the system will cancel all
pending alarms and send the restore codes. Programming 000-004 in this address disables this
feature. Maximum 30 seconds on UL listed systems.
[
ENTER
]
+
Installer Code
+
[10] [5] [9]
+
3-digit decimal value (005-063)
+
[
ENTER
]
8.10 Silent Zones & Silent Panics Option
Feature Select Programming
?
Address 086, key [9]
If the [9] key is on, silent zones or silent panics only transmit a report to the central station. The
system will not indicate an alarm and will not have to be disarmed.
Although, the control panel can still activate a PGM. If a keypad panic has been defined as audible,
the control panel will override this option.
Key [9] "Off": Silent Zones & Silent Panics generate a silent alarm
Key [9] "On": Silent Zones & Silent Panics generate a report only
[
ENTER
]
+
Installer Code
+
[10] [8] [6]
+
[9]
On/Off
+
[
ENTER
]
8.11 Bell Cut-Off Time
Decimal Programming
?
Address 052
Default: 5 minutes
After an audible alarm, the bell or siren will stop after the programmed time has elapsed.
[
ENTER
]
+
Installer Code
+
[10] [5] [2]
+
3-digit decimal value (001-255) minutes
+
[