12
ACCESS CODES
3.1
Installer Code
Streamline - Section 00
?
Hexa Programming - Addresses 000-002
Default: 748
=
484848
/ 748 EXPRESS
=
747474
Only the installer code allows you to program all control panel settings, except the Master and User
codes. To program any setting in the control panel you must enter the programming mode by
pressing the
[
ENTER
]
key followed by the installer code. The installer code contains six digits and
each digit can be any value from 0 to 9. Although the control panel can accept 4-digit codes, when
programming the installer code, always enter six digits. To change the installer code press:
[
ENTER
]
+
Installer Code
+
[10] [10] [10]
+
First 2 digits
+
[10] [10] [1]
+
Next 2 digits
+
[10] [10] [2]
+
Final 2 digits
+
[
ENTER
]
3.2
Master & User Codes
Default Master Code:
474747
You can not use the installer code to program the master and user codes. Only the master and
user 1 codes can program these access codes. (See section 11.1)
3.3
User / Access Code Length
Feature Select Programming
?
Address 088, key [9]
Default: 6-digit Access Codes
When programming user codes an option for either 4-digit or 6-digit access codes can be
programmed. When the 4-digit option is selected, entering a 4-digit code will allow the person
access. Using the 6-digit option, entering 6 digits is required to allow access.
Key [9] "Off": 6-digit Access Codes
Key [9] "On": 4-digit Access Codes
[
ENTER
]
+
Installer Code
+
[10] [8] [8]
+
[9]
On/Off
+
[
ENTER
]
twice
3.4
Duress
Feature Select Programming
?
Address 090, key [10]
Default: Duress Disabled
When unwillingly forced to disarm a system, a User can enter the User Code #48 instead of their
usual code. This code will disarm the system and send a silent alert (Duress Code) to the Central.
Key [10] "Off": Duress Disabled
Key [10] "On": Duress Enabled
[
ENTER
]
+
Installer Code
+
[10] [9] [10]
+
[10]
On/Off
+
[
ENTER
]
twice
3.5
Installer Lock
Decimal Programming
?
Address 058
Default: Address Empty
Program 147 into address 058 to lock all programming. Hence, performing a hardware reset (see section
10.12) will not affect the current settings. To remove the installer lock, enter any value besides 147.
[
ENTER
]
+
Installer Code
+
[10] [5] [8]
+
[1] [4] [7]
+
[
ENTER
]
Access Codes