18
Main Menu
?
Program Setup
?
Modem & Printer Configuration
Set "Dialing Condition" to "Blind Dial". Program the panel telephone number in Espload and follow
the instructions on the ADP-1 adapter. When the computer has dialed press:
[
ENTER
]
+
(Installer, Master, or User 1 Code)
+
[
AWAY
]
5.7
Cancel Communication
Key Access Programming
?
key [
STAY
]
Use the Installer Code to cancel all communication and erase any unreported events in the buffer
until the next reportable event. Use the Master or User 1 code to cancel communication attempts
with Espload.
[
ENTER
]
+
(Installer, Master & User 1 Code)
+
[
STAY
]
5.8
Call Back
Feature Select Programming
?
Address 086, key [4]
Default: Call Back Disabled
For additional security, when a PC using the Espload software attempts to communicate with the
control panel, the control panel can hang-up and call the PC back in order to re-verify identification
codes and re-establish communication. When the control panel answers the call, it will verify if the
Panel ID and PC Passwords match and if they do, the control panel will hang-up and call the
Espload software back. The Espload software will automatically go into "wait for dial tone", ready to
answer when the control panel calls back. Please note the
Computer Telephone Number
(see
section 5.4) must be programmed in order to use the "Call Back" feature.
Key [4] "Off": Call Back Disabled
Key [4] "On": Call Back Enabled
[
ENTER
]
+
Installer Code
+
[10] [8] [6]
+
[4]
On/Off
+
[
ENTER
]
twice
5.9
Automatic Event Buffer Transmission
Feature Select Programming
?
Address 088, key [2
ND
]
Default: Automatic Event Buffer Transmission Disabled
When the event buffer reaches 50% capacity, the control panel will make two attempts to establish
communication with a PC. The control panel will call the Computer Telephone Number (see section
5.4) programmed at addresses 008 to 015. The Espload software must be in "wait for dial tone"
mode. When the system establishes communication, it will upload the contents of the event buffer
to the Espload software. If communication is interrupted before transmission of the complete
contents of the buffer, or if after two attempts, communication is not established, the system will
wait until the event buffer is full before attempting to re-communicate with Espload. When the Event
Buffer is full, each subsequent new event will erase the oldest event in the buffer.
Key [2
ND
] "Off": Automatic Event Buffer Transmission Disabled
Key [2
ND
] "On": Automatic Event Buffer Transmission Enabled
[
ENTER
]
+
Installer Code
+
[10] [8] [8]
+
[2