27
6.11 Report Zone Restore Options
Feature Select Programming
?
Address 088; key [
BYP
]
Default: Zone Restore Codes Transmit on Bell Cut-Off
With the [
BYP
] key "Off", the report codes programmed at addresses 424-447 (see
Restore Codes
in
section 6.6.4) will only transmit if the zone has returned to normal after bell cut-off (see section 8.11).
With the [
BYP
] key "On", the codes will transmit as soon as the zone returns to normal (zone closure).
Key [
BYP
] "Off": Report on Bell Cut-Off
Key [
BYP
] "On": Report on Zone Closure
[
ENTER
]
+
Installer Code
+
[10] [8] [8]
+ [
BYP
]
On/Off
+
[
ENTER
]
6.12 Report Code Disarming Options
Feature Select Programming
?
Address 088; key [
TRBL
]
Default: Disarming Codes Transmit on User Disarming
With the [
TRBL
] key "OFF", the
Disarming Codes
programmed at addresses 350-399 (see in
section 6.6.2) will transmit whenever a User disarms the system. With the [
TRBL
] key "ON", the
control panel will transmit these codes when a User disarms a system in alarm.
Key [
TRBL
] "Off": Always Report Disarm
Key [
TRBL
] "On": Report Disarm Only After Alarm
[
ENTER
]
+
Installer Code
+
[10] [8] [8]
+
[
TRBL
]
On/Off
+
[
ENTER
]
Event Reporting