15
1) Press
[
ENTER
] +
Installer Code
2) The [
ENTER
] key will flash to indicate you
are in programming mode
3) Enter
3-digit address
(044-061)
4) The keypad will now display the current
3-digit data currently saved at this
address as described in figure 24
5) Enter
3-digit data
(decimal) value; after
entering data you do not need to press
[
ENTER
], the software will automatically
save the data into the selected address
6) Return to
step 2
to continue
programming or press
[
CLEAR
]
to exit
programming mode
4.2.4 Feature Select Programming
Addresses 062 to 126 are programmed using the Feature Select Programming method. In
this method, every key in each address on the keypad represents an option or feature.
Pressing a key will display it on the keypad and pressing it again will extinguish the key. The
On/Off status of each key determines the selected feature. To program using the Feature
Select Programming method:
1) Press
[
ENTER
]
+
Installer Code
2) The [
ENTER
] key will flash to indicate you are in programming mode
3) Enter
3-digit address
(062-126)
4) After entering the address, the keypad will display the feature selection status. The
On/Off status of the keys determines the selected features as described in the
"
Programming Guide
" and in the appropriate sections of this manual. Turn the keys
On/Off by pressing the appropriate key until the desired options are set. Then press the
[
ENTER
]
key to accept, there will be a confirmation "beep" indicating the options have
been accepted. The [
ENTER
] key will flash to indicate that the software is awaiting the
next address entry
5) Return to
step 3
to continue programming or press
[
CLEAR
]
to exit programming mode
4.2.5 Key Access Programming
This method allows for quick programming of features without entering addresses or section
numbers. The following features are programmed using the installer code as well as the
master and user 1 codes.
?
Installer Test Mode: see section 10.9
?
Auto Arm Time: see section 8.1.1
?
Cancel Communication: see section 5.7
?
Answer Espload: see section 5.6
?
Manual Test Report: see section 6.8
?
Call Espload: see section 5.5
?
Panel Time: see section 10.5
Programming Methods