zone you wish to bypass has not been programmed as "bypass enabled", the corresponding zone
indicator will never turn on. Press the [
CLEAR
] key to erase the current zone bypass entries and exit
the "bypass mode". If you have entered the correct bypass entries, press the [
ENTER
] key to accept
these entries. The [
BYP
] key will remain on, denoting that zones in the system are currently
bypassed, hence, the next time the system is armed, certain zones will be bypassed. When the
system is disarmed, the bypass entries will be erased.
11.10 Bypass Recall
This feature permits users to reinstate the last zone bypass entries saved in memory. When the system
is disarmed, the bypass entries will be erased. By using the "bypass recall" feature, you can reinstate the
previous bypass entries saved in memory. While in the "bypass mode", press the [
BYP
] + [
ENTER
] keys
and the previous bypass status will be re-established. This eliminates the need to re-enter the bypass
entries every time the system is armed. If a user is in the process of entering new bypass entries on the
keypad, pressing the [
BYP
] key will override new information and reinstate previous bypass entries.
11.11 Keypad Chime Zones
A chimed zone "advises" you when a zone is opened by creating a rapid intermittent beep tone
(
BEEP
-
BEEP
-
BEEP
-
BEEP
-
BEEP
). Up to six zones plus the local keypad zone can be programmed as
chime zones. To turn on the "chime zone" feature, press and hold the key corresponding to the
desired zone ([1] to [6]) for three seconds until the intermittent chime beep is heard. This means
that the chime feature has been activated. If a continuous beep is heard, this means that the chime
beep has been deactivated. To enable the chime feature on the keypad zone, press and hold the
[8] key for three seconds. To mute the keypad's alarm sounder, press and hold the [9] key for three
seconds until the intermittent chime beep is heard. This means that the muting feature has been
activated. If a continuous beep is heard, this means that the muting feature has been deactivated.
If there is more than one keypad in the system, please "chime" program each keypad separately.
Keypad chimes must be reprogrammed if the panel suffers a total power loss.
Key [1]-[6]: Turns chime "on" or "off" in zones numbered 1-6
Key [8]:
Turns chime "on" and "off" for the local keypad zone
Key [9]:
Turns the keypad's alarm sounder muting "on" or "off"
11.12 Trouble Display Monitoring
Trouble conditions are continuously monitored by the control panel, which recognizes and displays
10 different trouble conditions on the keypad. When a trouble condition occurs, the [
TRBL
] key will
illuminate and the keypad will emit an intermittent beep if the
Audible Trouble Warning
(see section
10.11) is enabled. Press the [
TRBL
] key to switch to "trouble display" mode. The [
TRBL
] key will flash
and any illuminated keys correspond to a current trouble condition as described below. Press any
key to exit the "trouble display" mode.
11.12.1 No Battery/Low Battery - Key [1]
The control panel conducts a dynamic battery test under load every 60 seconds. The
illumination of the [1] key indicates that the back-up battery is disconnected or that the battery
should be replaced, as it will not provide adequate back-up current in case of AC loss. If the
control panel is currently running on battery power, the illumination of the [1] key indicates
that the battery voltage has dropped to 10.5 volts or lower.
11.12.2 Power Failure - Key [2]
The control panel conducts a dynamic battery test under load every 60 seconds. The control