Settings
34
【
Arc control
】
NO.
Menu contents
Set range
Increment
Default
Note
P01
Arc ignition
energy
compensation
-50
~
50
1
0
Fine adjustment of peak current of arc.
It increases when the direction is adjusted
positive value.
P02
Arc ignition
voltage
compensation
-5
~
5
1
0.1
Fine adjustment of the arc voltage value.
The peak current of the arc is increased
when the direction is adjusted positive
value.
P03
Arc ignition time
compensation
-50
~
50
1
0
The role of micro-adjustment of the arc
voltage.
Positive value direction of the arc voltage
adjustment time longer.
【
Pulse control
】
NO.
Menu contents
Set range
Increment
Default
Note
P15
Dual-pulse
frequency
※
5
-5 Hz
~
5 Hz
0.1Hz
0
P16
Low pulse
duty ratio
-50
~
50
1
50
the second pulse output duty ratio.
P17
Low pulse
current
-50
~
200
1
120
Low pulse current set point.
P18
low pulse
voltage
-9.9V
~
9.9V
0.1V
0V
Voltage compensation for the unified voltage.
P19
Double pulse
(MUP) enabled
0 1 or 2
1
0
0: normal pulse
1:double pulse
2:pulse + Short circuit
※
5 Double pulse: In the original pulse (high pulse part), based on the increase in the low pulse part.c
Summary of Contents for YD-500GP5
Page 11: ...Rated Specifications 7 2 4 Dimensions 机型 W H L YD 500GP5HNX 383 1240 840 ...
Page 29: ...Connection 25 ...
Page 30: ...Connection 26 ...
Page 31: ...Connection 27 ...
Page 43: ...Operation 39 9 3 CRATER Operation Turn the torch switch on and off twice ...
Page 54: ...Parts list 50 12 Parts list 12 1 Parts list for GP5 Front view Rear view Top view 20 101 ...
Page 55: ...Parts list 51 Right view Left view 35 4 26 25 8 2 6 9 7 5 26 14 10 40 59 60 61 30 106 ...
Page 56: ...Parts list 52 30 102 103 104 105 24 ...
Page 60: ...Circuit diagram 56 13Circuit diagram 13 1 Circuit diagram for YD 500GP5 ...