Rated Specifications
6
2.2 Rated duty cycle
■
YD-500GP5
●
The rated duty cycle is 60 %. This means that the machine can cut for a total of 6 minutes out of any 10 minutes at the
rated current, and then, during the remaining 4 minutes, the machine must be cooled down to prevent overheating.
●
Exceeding allowable duty cycle can cause the temperature rise higher than the maximum allowable temperature,
resulting in the performance degradation or damage.
●
The figure above shows the ideal value of cutting current and duty cycle. Please use the machine within the
corresponding duty cycle of cutting current.
2.3 Thermal protection
●
Cutting power source is equipped with a thermal switch at the radiator fin of IGBT to monitor the temperature.
●
When the abnormal temperature happens, the thermal switch takes action and cut off the output.
●
Please be sure not to use under the conditions listed here:
●
Over the rated output voltage.
●
The air inlet or outlet is blocked.
●
The ambient temperature is higher than 40°C.
●
The cooling fan stops.
Summary of Contents for YD-500GP5
Page 11: ...Rated Specifications 7 2 4 Dimensions 机型 W H L YD 500GP5HNX 383 1240 840 ...
Page 29: ...Connection 25 ...
Page 30: ...Connection 26 ...
Page 31: ...Connection 27 ...
Page 43: ...Operation 39 9 3 CRATER Operation Turn the torch switch on and off twice ...
Page 54: ...Parts list 50 12 Parts list 12 1 Parts list for GP5 Front view Rear view Top view 20 101 ...
Page 55: ...Parts list 51 Right view Left view 35 4 26 25 8 2 6 9 7 5 26 14 10 40 59 60 61 30 106 ...
Page 56: ...Parts list 52 30 102 103 104 105 24 ...
Page 60: ...Circuit diagram 56 13Circuit diagram 13 1 Circuit diagram for YD 500GP5 ...