Names and functions
17
5.3 Front panel
Note:
for robot welding, be sure to set the machine on “ crater OFF ” status.
NO.
name
description
○
1
temperature
abnomal indicator
●
When abnormal rise in important components temperature occurs, temperature
abnomal alarm is sent, this lamp blinks and the welding operation stops. Welding
operation cannot be restarted unless this lamp is turned off. ( For troubleshooting:
Section 13.1).
○
2
current display
7-segment LED
●
When Mode selection key
○
12
・
On stand-by status,, it shows the current value set in
is set to“ Weld ”
○
3
・
During welding, it shows the current value of the actual output.
●
When Mode selection key
○
12
is set to“F. Adj” (
Section 5.4)
・
It shows fine adjusting setting items PXX(XX stands for 00->29), default display
CH-OFF( voltage display LED
○
5
shows its specific set value ).
●
When Mode selection key
○
12
is set to “ Call ” (
Section 5.6)
・
The default display CH-OFF. By turning the Jog-dial
○
7
, select channel number,
LED shows “CH” channel. If welding parameters are available, the channel can be
selected, else the corresponding channel can NOT be selected. When the channel
stored with data is selected, the channel and parameters are displayed alternately
and welding can start.
●
When Mode selection key
○
12
is set to “ Record ” (
Section 5.6)
・
By turning the Jog-dial
○
7
, channel number can be selected. LED shows “CH”
setting current and voltage. Flashing means welding parameters are being stored.
・
Press selection key
○
12
to return to “ Weld ” from “ Record ” and the corresponding
parameters are recorded in the channel being selected.
●
When a self-diagnosable error occurs, ( For troubleshooting:
Section 13.1)
・
it shows Err( voltage display LED
○
3
shows alarm signal number ).
○
3
setting
“ current ”
“ wire feeding
speed ”
“ plate thickness ”
“ spot welding
time ”
function
的
select
●
When “ current ” / “ wire feeding speed ” function is selected, the setting method of
the corrosponding selection number is decided by P11 of “F. Adj” function menu.
When P11 is 0, it is adjusted by wire feeder potentiometer; when P11 is 1, it can
be changed by Jog-dial
○
4
. Note “ plate thickness ” can be displayed only instead
of being changed.
●
“ spot welding time ” function is adjusted by Jog-dial
○
4
Note To change“ spot welding time ”, welding control
.
○
13
is to be selected as “ spot
welding ” function.
Summary of Contents for YD-500GP5
Page 11: ...Rated Specifications 7 2 4 Dimensions 机型 W H L YD 500GP5HNX 383 1240 840 ...
Page 29: ...Connection 25 ...
Page 30: ...Connection 26 ...
Page 31: ...Connection 27 ...
Page 43: ...Operation 39 9 3 CRATER Operation Turn the torch switch on and off twice ...
Page 54: ...Parts list 50 12 Parts list 12 1 Parts list for GP5 Front view Rear view Top view 20 101 ...
Page 55: ...Parts list 51 Right view Left view 35 4 26 25 8 2 6 9 7 5 26 14 10 40 59 60 61 30 106 ...
Page 56: ...Parts list 52 30 102 103 104 105 24 ...
Page 60: ...Circuit diagram 56 13Circuit diagram 13 1 Circuit diagram for YD 500GP5 ...