Maintenance and inspection
43
10 Maintenance and inspection
Touching any current-carrying parts may cause a fatal electric shock
or burn injury
To prevent a fatal accident, such as an electric shock, burn injury, etc., make
sure to observe the followings.
Make sure to turn off the power switch and the switch of the distribution box before making
a daily check. (However, any external check made without touching current-carrying parts
or their surrounding area is excluded.)
10.1 Daily check
●
Perform the daily check without fail. It is important to make the most of the performance of this product and
to secure the safety of daily operations.
●
Check the items indicated in the following table, and conduct the cleaning and replacement of parts when
necessary.
10.1.1
Welding machine (This product)
●
For replacement of parts, make sure to use our genuine parts for Panasonic welding machine to keep its
performance and functions
Check item
Check point
Remarks
Front panel
Devices on the front panel
Breakage or loose attachment.
If there is any defect, an
inside check, additional
fastening, parts replacement,
etc. are required.
Terminal cover at the
bottom
If it is fixed with screws.
Rear panel
Input power terminal cover
•
If the cover is attached correctly.
•
Breakage or loose attachment.
•
Check if any foreign matter is
attached to the cooling air intake
vent
Top panel
Bottom panel
Side panel
Eyebolts and other bolts
Breakage or loose attachment.
If there is any defect,
additional fastening, parts
replacement, etc. are
required.
Casters
Breakage or loose attachment.
Panels
Loose attachment.
Overall
Appearance
Check if there is any trace of heat
generation, such as discoloration.
If there is any unusual events,
an inside check is required.
After turning ON the power switch, check the followings
•
If the cooling fan makes unusual rotation noise.
•
If the cooling fan generates cooling wind all right.
•
If there is any unusual vibrations, beats or odor.
Note:
The parts behind the terminal cover at the bottom are periodical check items.
10.1.2
Cables
Check item
Check point
Remarks
Grounding wires
*
If each grounding wire is connected all right and
fastened securely.
To prevent a physical accident caused by
electric leakage, make sure to check it.
Other cables
•
If cable coating is worn or damaged.
•
If any current-carrying parts is exposed.
•
If any heavy items not placed on the cable.
•
If the connection of the base metal cable is
fastened securely.
To secure the physical safety and
stable arc, check those cables in an
appropriate manner according to the
conditions of shop floors.
Daily check: Quick and rough
check Period check: Thorough check
*
Check grounding wires for perhipheral equipment, such as base metal and water cooling unit as well as for this
product.
Summary of Contents for YD-500GP5
Page 11: ...Rated Specifications 7 2 4 Dimensions 机型 W H L YD 500GP5HNX 383 1240 840 ...
Page 29: ...Connection 25 ...
Page 30: ...Connection 26 ...
Page 31: ...Connection 27 ...
Page 43: ...Operation 39 9 3 CRATER Operation Turn the torch switch on and off twice ...
Page 54: ...Parts list 50 12 Parts list 12 1 Parts list for GP5 Front view Rear view Top view 20 101 ...
Page 55: ...Parts list 51 Right view Left view 35 4 26 25 8 2 6 9 7 5 26 14 10 40 59 60 61 30 106 ...
Page 56: ...Parts list 52 30 102 103 104 105 24 ...
Page 60: ...Circuit diagram 56 13Circuit diagram 13 1 Circuit diagram for YD 500GP5 ...