Settings
36
8.1.2 “CALL” and “RECORD”
Reminder
when delivery, Record & Call functions are set as disabled status.
●“Call” is a function to use stored welding conditions and “Record” is to store the well
-tuned welding conditions.
Record/Call operation is applicable to the set values of current
・
voltage, spot welding time, arc characteristics,
penetration control, welding control, pulse ON/OFF, material, wire diameter, gas and F. Adj.
■
“ Call ” operation
Reminder
During the selection of Call, welding condition can NOT be changed (gas check and manual wire
feeding function work.)
No.
Operation
7-segment LED
1
Select Call in
○
12
CH
OFF
( as shown in the picture on the right )
2
Select channel (CH1-CH100) to be called in
○
7
(It alternately shows “CH” and current set value in
○
2
, channel and
voltage set value in
150
19.2
CH
1
交
替
显
示
○
5
)
3
At present, ( welding condition is already being called) welding can
start.
4
After operation finishes, select
○
12
and return to “ welding ” mode
■
“ Record ” operation
Reminder
During Record operation, welding can’t start. (Gas check works.).
No.
Operation
7-segment LED
1
Select Record in
○
12
CH
OFF
( as shown in the picture on the right )
2
Select the channel (CH1-CH100) to be used in
○
7
.
(It alternately shows “CH” and current set value in
○
2
,
channel and
voltage set value in
○
5
150
19.2
CH
1
交
替
显
示
)
3
After operation finishes, select
○
12
and return to “ welding ” mode. Till
now data recording finishes.
Note:
During Call operation,
○
13
○
14
○
15
○
16
○
17
8.2 The welding machine factory defaults reset
operation does not function.
●
If 7-segment LED cannot display correctly after turning ON the power source, the damage of internal data may
happen. Please follow the steps here to restore machine to factory settings.
●
The operation sequence
1
.
Disconnect power source
;
2
.
After connecting the power source, at the moment when the software version is shown, hold
【
lock
】
and
【
welding control
】
button at the same time for 2 seconds. After welding machine finishes the display of the
software version, the display shown on the below picture happens. Thus the default setting is done successfully.
Please disconnect power source
;
- - -
- - -
2
5
Note:
Only when the display shown on the above picture on the welding machine, the power source can be switched off,
otherwise wrong operation would lead to the failure of the operation. And the second step should be done again.
3
.
After turning the power source again, welding machine restores to factory settings
;
4
.
Because the recorded data is reset to factory settings, please set according to your requirement.
Note:
During welding, there are certain errors of current and voltage between the value shown on LED and preset value.
It’s not a machine problem. During actual welding, the factors such as gas, wire diameter, welding technique and
extension length etc. can generate the above-mentioned errors.
A
lt
er
nat
e
disp
lay
A
lt
er
nat
e
disp
lay
Summary of Contents for YD-500GP5
Page 11: ...Rated Specifications 7 2 4 Dimensions 机型 W H L YD 500GP5HNX 383 1240 840 ...
Page 29: ...Connection 25 ...
Page 30: ...Connection 26 ...
Page 31: ...Connection 27 ...
Page 43: ...Operation 39 9 3 CRATER Operation Turn the torch switch on and off twice ...
Page 54: ...Parts list 50 12 Parts list 12 1 Parts list for GP5 Front view Rear view Top view 20 101 ...
Page 55: ...Parts list 51 Right view Left view 35 4 26 25 8 2 6 9 7 5 26 14 10 40 59 60 61 30 106 ...
Page 56: ...Parts list 52 30 102 103 104 105 24 ...
Page 60: ...Circuit diagram 56 13Circuit diagram 13 1 Circuit diagram for YD 500GP5 ...