Configuration
12
4.2 Connecting cable
Caution against getting the cable wet.
Avoid the connecting cable to get wet.
If there is a chance of getting the cable exposed to rain or water splay,
make sure to protect the connection with waterproof cover.
Water seeping into the machine may degrade the insulation between
terminals, which may cause an error or damage this product or wire
feeder.
4.2.1
About connecting cable
●
The connecting cable (separately sold) is useful to expand the working space in welding operation. (See
the table on the right for model numbers.)
●
Apply the connecting cable between torch output terminal (+) of the product and the torch cable of the wire
feeder.
●
Depending on work conditions, it may be necessary to extend the base metal cable.
Note:
It is not possible to use the connecting cable as a junction cable.
4.2.2
Cautions about using connecting cable
●
Select a model properly and use connecting cable properly, or adverse impact on welding operation, such as
voltage drop, may result. Voltage drop may be resulted from the reactance caused by the conductor resistance
or cable routing manner. The longer the cable is or smaller the cross section is, the more likely an adverse
impact occurs.
●
To minimize such adverse impact, pay attention to the fol- lowing points.
(
1
)
Relationship among extending length, cross section, allowable current and duty cycle.
(
2
)
Arrange the base metal cable corresponding to the applied connecting cable.
(
3
)
Do not extend the cable unnecessarily. (A shorter cable is preferable)
(
4
)
Do not use leave the connecting cable slackened. Never coil the connecting cable when welding, or the
welding arc may become unstable.
(
5
)
Connect the base metal voltage detection wire (-) to the base metal voltage detection terminal (-).
(
6
)
Do not use the connecting cable as a junction cable.
Welding power source
Cross section
Length
YD-500GP5
70 mm
2
L
≤18.2 m
Summary of Contents for YD-500GP5
Page 11: ...Rated Specifications 7 2 4 Dimensions 机型 W H L YD 500GP5HNX 383 1240 840 ...
Page 29: ...Connection 25 ...
Page 30: ...Connection 26 ...
Page 31: ...Connection 27 ...
Page 43: ...Operation 39 9 3 CRATER Operation Turn the torch switch on and off twice ...
Page 54: ...Parts list 50 12 Parts list 12 1 Parts list for GP5 Front view Rear view Top view 20 101 ...
Page 55: ...Parts list 51 Right view Left view 35 4 26 25 8 2 6 9 7 5 26 14 10 40 59 60 61 30 106 ...
Page 56: ...Parts list 52 30 102 103 104 105 24 ...
Page 60: ...Circuit diagram 56 13Circuit diagram 13 1 Circuit diagram for YD 500GP5 ...