8.31.2. Installation
CAUTION!
Turn the Power Switch on the Left Side and the Main Power Switch on the Back of the
machine to the OFF position, and then unplug the AC Power Cord before beginning
installation.
(1) Remove the Glass Assembly.
(Refer to 2.2.3. of the Service Manual)
(2) Remove 7
Screws
.
(3) Remove the
CCD Cover
.
(4) Disconnect the
CCD Harness
.
Note:
(For Euro Destination only)
The EMI Bracket is already installed, remove it
first.
(5) Mount the
Heater
(with Heat Sheet) onto the
Dehumidifier Bracket.
(6) Install the
Heater
Assembly.
(7) Secure the
Heater
Assembly with
1 Screw (XTB3+6J).
(8) Route the
Harness
of the Heater Assembly to
the lower section of the frame through the
access hole as illustrated.