8.2.
Service Notes
"
Firmware Update
"
for PCL or PS Option Installation
(For DP-2310/3010)
To use
PCL (DA-PC300)
or
PS (DA-MC300)
option individually or in combination with other options,
changing to
Type B
or
Type D
SC firmware is required. The required firmware is on the CD included with
the options.
Note:
The DA-EM600 must be installed for the printer controllers above to function. The only time a DA-EM600
is needed is if you are installing the PostScript (PS) or PCL option. There will never be a need for 2 of
these, even if there are other options, such as Fax, added.
Before proceeding, it is important to determine the Final Configuration of your machine in order to correctly
identify the required firmware from the table below. Carefully read and follow the Installation Instructions for
the appropriate option.
The firmware for SC, SPC and PNL must be updated in this sequence as a set. Please update the firmware
with the latest version as a set by referring to the following table.
Firmware Version Table (For DP-2310/3010)
Standard Firmware
(SC = Type A)
PCL Firmware
(SC = Type B)
PostScript Firmware
(SC = Type D)
SC
DP-SFDL2
A
xVxxxxx_xx DP-SFDL2
B
xVxxxxx_xx DP-SFDL2
D
xVxxxxx_xx
PNL
SFDL2PNLAxVxxxxx_xx
←
←
SPC
SFDL2SPCAxVxxxxx
←
←
Slot 1 FROM PCB
Not Required
Required
Required