207
DP-2330/3030
MAR 2005
Ver. 2.1
DP-2310/3010
026 Non-Standard
1 = Off (Invalid)
2 = On (Valid)
Selects own mode (Panafax mode).
027 Short Protocol B 1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode.
028 Short Protocol D 1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode. When activated, it
allows the machine to automatically store the
modem speed for each Auto Dial Number.
029 Remote
Diagnostics
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts Remote
Diagnostics from the service station.
030 CED & 300 bps
1 = 75 ms
2 = 1 sec
Selects the pause interval between the CED and the
300 bps signal.
(Used when Echo Suppression is disabled.)
031 RTC = EOL x 12 1 = Off (EOLx6)
2 = On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
032 V34 TX Start
2400-33600bps
Selects the transmission modem start speed for V.34
communication, 33600-2400 bps.
033 V34 RX Start
2400-33600bps
Selects the receiving modem start speed for V.34
communication, 33600-2400 bps.
034 V34 TX SR
2400-3429sr
Selects the transmission symbol rate for V.34, 3429/
3200/3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
035 V34 RX SR
2400-3429sr
Selects receiving symbol rate for V.34, 3429/3200/
3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
036 Not Used
037 Protocol Display 1 = Off (not displayed)
2 = On (displayed)
Selects whether to display the modem speed during
communication.
(Press the Job Status Key to display)
038 Not Used
039 Flash Time
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
040 Flash Time
(PSTN)
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the Flash
key.
(For Germany, Austria and Czech)
041 Pause Time
1 = 1 sec.
~
10 = 10 sec.
Selects the pause interval from 1 sec. ~ 10 sec. for
dialing through a switchboard or for international
calls.
042 Not Used
043 Redial Interval
0 = no waiting
~
15 = 15 minutes
Selects the redial interval from 0 to 15 minutes in 1
minute steps.
044 Redial Count
0 = no redial
~
15 = 15 times
0 ~ 9 (For Australia Only)
Selects the redial count from 0 to 15 times in 1 step
intervals.
Note:
In order to comply with the requirements TBR21
in the EC countries, do not select 15 times.
045 Ring Detect
Count
1 = 1 ring
~
9 = 9 rings
Selects the ring detection count from 1 to 9 rings in 1
ring step intervals.
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for Workio DP-3030
Page 4: ...4 Beispiel DP 2330 3030 Hinweis...
Page 8: ...8 memo...
Page 35: ...35 DP 2330 3030 MAR 2005 Ver 2 1 DP 2310 3010 1 6 Control Panel DP 2310 3010 DP 2330 3030...
Page 454: ...memo...
Page 470: ...memo...
Page 486: ...DZZSM00270...