45
Connection for emergency recording
When the external switch is turned on, emergency recording will start.
Emergency recording will differently be performed depending on the settings on the [Emergency rec.] tab under the "Basic" page
of the setup menu. (
+
Page 70)
Connection for external recording mode changeover
When the external switch is set to "On", recording will start after changing the recording program.
The recording program can be set on "Time table setup(Ext.)" on the [Time table] tab under the "Schedule" page of the setup
menu (
+
Page 81).
Connection for synchronization of the sequence switchover
Camera channel of the sequence display will be switched upon the signal input to the sequence switchover input. When using
multiple recorders, it is possible to synchronize the switchover timing.
The setting for the sequence switchover timing can be configured on "Sequence timing" on the [Monitor 1] tab (or "Monitor 2"
tab) under the "Display" page of the setup menu (
+
Pages 86 and 88).
When synchronizing the sequence switchover timing between multiple recorders, the setting for the sequence switchover timing
is differently configured between the master recorder and the slave recorder as follows.
Master recorder:
Set to "Int" (functions as the output terminal)
Slave recorder:
Set to "Ext" (functions as the input terminal)
12
13
ALARM/CONTROL
(Signal ground)
(Emergency recording input)
External switch
24
13
ALARM/CONTROL
(Signal ground)
(External recording mode changeover)
External switch
21
13
21
13
ALARM/CONTROL
WJ-HD616K (First)
(Signal ground)
(Signal ground)
(Sequence switchover output)
(Sequence switchover input)
ALARM/CONTROL
WJ-HD616K (Second)
Summary of Contents for WJ-HD616/1000
Page 155: ...155...