Connection of a PC
Connect a PC and the recorder. Required devices and cables vary depending on how to connect them. Before starting the con-
nection, prepare the required devices and cables.
Connect a PC and the recorder directly
Use a LAN cable to connect a PC and the recorder directly.
Important:
• When connecting a PC and the recorder directly (without using a hub/router), make sure to use a cross LAN cable.
• This connection is only for the setting configuration. Operation of the recorder cannot be performed by this connection.
Add the recorder to the existing network
EXT STORAGE
MODE
DATA
RS485(CAMERA) 10/100BASE-T
ALARM
VIDEO
OUT-CASCADE-IN
ALARM/CONTROL
CASCADE IN
MONITOR
OUT
OUT MONITOR OUT(HD)
AUDIO IN
AUDIO
OUT
3
2
1
1 2 3 4 5 6 7 8
1
2
3
4
4
2
3
1
1
2
5
6
7
8
9
10
11
12
13
14
15
16
IN
OUT
2
1
3
4
5
6
7
7
1
2
1
2
8
9
10
11
12
13
14
15
16
POWER
AC IN
SIGNAL
GND
ON
OFF
OUT
IN
OUT
CASCADE
1
2
EXT STORAGE
MODE
DATA
RS485(CAMERA) 10/100BASE-T
ALARM
VIDEO
OUT-CASCADE-IN
ALARM/CONTROL
CASCADE IN
MONITOR
OUT
OUT MONITOR OUT(HD)
AUDIO IN
AUDIO
OUT
3
2
1
1 2 3 4 5 6 7 8
1
2
3
4
4
2
3
1
1
2
5
6
7
8
9
10
11
12
13
14
15
16
IN
OUT
2
1
3
4
5
6
7
7
1
2
1
2
8
9
10
11
12
13
14
15
16
POWER
AC IN
SIGNAL
GND
ON
OFF
OUT
IN
OUT
CASCADE
1
2
IP address 192.168.0.x (except 0, 250 and 255)
Subnet mask 255.255.255.0
Recorder
IP address 192.168.0.250
Subnet mask 255.255.255.0
LAN cable
(locally procured: 10BASE-T/100BASE-TX,
category5, cross)
PC
PC
Recorder
IP address 192.168.0.250
Subnet mask 255.255.255.0
Gateway address: 192.168.0.1
LAN cable
(locally procured: 10BASE-T/
100BASE-TX, category5, straight)
IP address 192.168.0.x
(except 0, 1, 250 and 255)
Subnet mask 255.255.255.0
Gateway address: 192.168.0.1
LAN*
Hub/Router
IP address: 192.168.0.1
Subnet mask: 255.255.255.0
FTP server
(for image transmission)
* Stands for Local Area Network
EXT STORAGE
MODE
DATA
RS485(CAMERA) 10/100BASE-T
ALARM
VIDEO
OUT-CASCADE-IN
ALARM/CONTROL
CASCADE IN
MONITOR
OUT
OUT MONITOR OUT(HD)
AUDIO IN
AUDIO
OUT
3
2
1
1 2 3 4 5 6 7 8
1
2
3
4
4
2
3
1
1
2
5
6
7
8
9
10
11
12
13
14
15
16
IN
OUT
2
1
3
4
5
6
7
7
1
2
1
2
8
9
10
11
12
13
14
15
16
POWER
AC IN
SIGNAL
GND
ON
OFF
OUT
IN
OUT
CASCADE
1
2
EXT STORAGE
MODE
DATA
RS485(CAMERA) 10/100BASE-T
ALARM
VIDEO
OUT-CASCADE-IN
ALARM/CONTROL
CASCADE IN
MONITOR
OUT
OUT MONITOR OUT(HD)
AUDIO IN
AUDIO
OUT
3
2
1
1 2 3 4 5 6 7 8
1
2
3
4
4
2
3
1
1
2
5
6
7
8
9
10
11
12
13
14
15
16
IN
OUT
2
1
3
4
5
6
7
7
1
2
1
2
8
9
10
11
12
13
14
15
16
POWER
AC IN
SIGNAL
GND
ON
OFF
OUT
IN
OUT
CASCADE
1
2
IP address 192.168.0.x (except 0, 250 and 255)
Subnet mask 255.255.255.0
Recorder
IP address 192.168.0.250
Subnet mask 255.255.255.0
LAN cable
(locally procured: 10BASE-T/100BASE-TX,
category5, cross)
PC
PC
Recorder
IP address 192.168.0.250
Subnet mask 255.255.255.0
Gateway address: 192.168.0.1
LAN cable
(locally procured: 10BASE-T/
100BASE-TX, category5, straight)
IP address 192.168.0.x
(except 0, 1, 250 and 255)
Subnet mask 255.255.255.0
Gateway address: 192.168.0.1
LAN*
Hub/Router
IP address: 192.168.0.1
Subnet mask: 255.255.255.0
FTP server
(for image transmission)
* Stands for Local Area Network
Summary of Contents for WJ-HD616/1000
Page 155: ...155...