12
UF-5500 / 4500
1 Power Requirement
120 VAC, 60 Hz, Single Phase
2 Power Consumption
Standby
ES: Energy Saver
ES=On
5.5 Wh
Reception
500 W
Copy
500 W
Maximum
950 W
Environment
1 Temperature
Operation
50 to 90.5
°
F (10 to 32.5
°
C)
Storage
32 to 104
°
F (0 to 40
°
C)
Transport (Max. 72 H)
32 to 104
°
F (0 to 40
°
C)
2 Relative Humidity
Operation
20 to 70 % RH
Storage (Max. 120 H)
20 to 80 % RH
Transport (Max. 120 H)
20 to 80 % RH
Standards
1 Safety
UL60950-1
2nd Edition,2007-03-27 (AC)*
CSA C22.2 No.60950-1-07 (AC)*
*Canada only
*Canada only
2 PSTN
FCC Part 68
FCC Part68/IC.CS-03 (AC)*
*Canada only
3 EMI
Class B computing device
in FCC Part 15 Subpart B
Construction
1 Dimensions (W x D x H)
Approx. width 16.5 x depth 18 x heght
11.7 in (420 mm x 457 mm x 297 mm)
Excluding projections and
Optional Paper Cassette.
2 Weight (Excluding paper)
Approx. 27.8 lb (12.5 kg)
Including starter consumable
supplies.
Attachment & Accessories
Toner Cartridge
Drum Cartridge
User’s Guide
Power Cord
Tel Line Cable
Document Trays (RX)
Document Trays (TX)
CD-ROM
Yes (1)*
Yes (1)
Yes (1)
Yes (1)
Yes (1)
Yes (1)
Yes (1)
Yes (1)*
Yes (1)*
Yes (1)
Yes (1)
Yes (1)
Yes (1)
Yes (1)
Yes (1)
Yes (1)
*Yield 500 sheets as a starter
Specified countries only
*Include PC software
Consumables
1 Process Type
Separate (2 pieces)
2
Toner Yield
3% Black Chart
(ITU-T Image No. 1
Chart)
Approx. 3,000 sheets
Multiple copy mode Operation
Environment 73.4
°
F (23
°
C),
50%RH, using A4 paper.
3 OPC Yield
Approx. 6,000 sheets
Items
Description
Remarks
UF-5500
UF-4500
Summary of Contents for UF-4500
Page 180: ...180 UF 5500 4500 ...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart ...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart ...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30 ...
Page 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1 ...
Page 297: ...297 UF 5500 4500 ...
Page 305: ...305 UF 5500 4500 ...
Page 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52 ...
Page 362: ...362 UF 5500 4500 ...