158
UF-5500 / 4500
401
XMT
B
DCN was returned from receiver while
transmitter is waiting for CFR or FTT.
Your machine's ID Number is not programmed.
Possible incompatibility or incorrect Password.
402
XMT
B
DCN was returned from receiver while
transmitter is waiting for NSF/DIS.
Receiver working in NON-STD mode only.
(Possible incompatibility)
403
RCV
(Polling)
B
Transmitter had no polling function.
"POLLED=ON" (polling XMT ready) is not set at
the transmitter.
Document to be transmitted is not placed at the
transmitter.
404
XMT
B
Transmitter sent NSS (or DCS) followed by
TCF three times, but the receiver did not
respond. (CFR or FTT is usually returned)
Receiver is defective. (Modem, MAIN PCB, etc.)
MAIN PCB is defective.
Receiver disconnects line during first NSS (or
DCS) is transmitted.
405
XMT
B
Transmitter received FTT after it
transmitted TCF at 2400bps.
Received RTN after communicating at
2400 bps.
Line quality is poor. (TCF is damaged due to line
noise)
Receiver is defective. (Modem, etc.)
MAIN PCB is defective.
406
RCV
(Password
Comm.)
B
XMT-Password mismatched.
RCV-Password mismatched.
Selective RCV incomplete.
XMT, RCV password does not match.
Last 4 digits of TSI does not match with the last
4 digits of ONE-TOUCH, ABBR telephone num-
ber.
407
XMT
D
Transmitter received no response after it
transmitted post message, such as EOP,
MPS, EOM, etc...or received DCN.
Receiver is defective. (No paper, paper jam-
ming, etc.)
Receiver ceased receiving because of exces-
sive error. (Line quality is poor)
MAIN PCB (Modem) is defective.
408
XMT
D
Transmitter received RTN after it transmit-
ted EOP, MPS, or EOM.
Receiver receives data with error. (Line quality is
poor)
Receiver is defective. (Modem, etc.)
MAIN PCB is defective.
409
XMT
D
Transmitter receives PIN after it transmitted
a post message, such as EOP, MPS, EOM,
etc.
Receiver receives data with error due to poor
line quality, and receiving operator requests
voice contact.
Receiver is defective. (Modem, etc.)
MAIN PCB is defective.
410
RCV
D
Received DCN while waiting for post com-
mand. (EOP, MPS, EOM, etc.)
Interface or line is faulty.
Transmitter is defective.
411
RCV
(Polling)
B
Received DCN after transmitting NSC.
Transmitter is not ready for polling communica-
tion.
Password does not match between transmitter
and receiver.
412
G3 RX
B, D
No response within 12 seconds in NSS/
DCS/MPS wait state. (After transmitting
FTT)
Transmitter is defective.
MAIN PCB is defective.
414
RCV
(Polling)
B
No response received after transmitting 3rd
NSC.
Password does not match between transmitter
and receiver.
Transmitter is defective. (No original, document
jam, etc.)
415
XMT
(Polling)
B
Remote side attempted to receive message
from your machine in polling communica-
tion.
Inform the remote side that your machine does
not have the polling transmission feature.
416
RCV
D
Receiver did not detect post command,
such as EOP, MPS, EOM, etc.
Transmitter is defective.
Line quality is poor. (RTC signal is distorted due
to line noise)
MAIN PCB is defective.
417
RCV
C
Receiver returned RTN in response to post
message.
Line quality is poor. (There are excessive errors
in received data)
MAIN PCB is defective.
420
RCV
B
T1 timer (35 sec.) elapsed without detect-
ing 300 bps signal.
There is wrong incoming call. (non-facsimile
communication)
Transmitter is defective.
MAIN PCB is defective.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for UF-4500
Page 180: ...180 UF 5500 4500 ...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart ...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart ...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30 ...
Page 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1 ...
Page 297: ...297 UF 5500 4500 ...
Page 305: ...305 UF 5500 4500 ...
Page 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52 ...
Page 362: ...362 UF 5500 4500 ...