10.1.4.2. Tonal Signal
This Service Mode is used to check the tonal signal output. Signals can be output to the line using the
following procedure.
Tonal Signal Table
Service Mode 4 - Tonal Signal
Step
Operation or Unit Condition
LCD Display
(The pictured model is UF-5500.)
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Enter the key operator password (The factory default ID is 00000000.) and press
"Set".
5
Press “4”.
6
Press “2” and “START”.
7
Enter the signal number (1-8) to select the binary signal.
8
Press "CLEAR" to end the signal generation. To select another signal, repeat step 7.
9
Press "STOP" twice to return to standby.
Number
Signals
1
462 Hz
2
1080 Hz
3
1100 Hz
4
1300 Hz
5
1650 Hz
6
1850 Hz
7
2100 Hz
8
RBT