94
UF-5500 / 4500
Function Parameter Table
No.
Parameter
Selections
Function
000
MON/TEL DIAL
1 = Monitor
2 = TEL/DIAL
Selects whether the machine starts to TX automatically during
On-Hook dialing.
Monitor
: Start to TX after pressing START
TEL/DIAL
: Start to TX automatically
001
ALARM STATUS
1 = OFF
2 = Timer (6 sec.)
3 = Constant
Selects the No Paper or No Toner alarm status.
OFF
: Alarm is disabled.
Timer
: Alarm will shut off after 6 seconds.
Constant
: Alarm will not stop until "STOP" is pressed or the
error is cleared/corrected.
002
STOP COMM.
JRNL
1 = Off
2 = On
Selects whether the machine prompts to print the COMM.
Journal when the printout condition is set to INC and STOP is
pressed during communication.
003
CONTINUOUS
POLL
1 = Off
2 = Stn (Tx only)
Selects whether the Continuous Polling feature is enabled.
Stn
:
Place the document(s) on the ADF then press the Program Key
[P4] to store or add the document(s) into a polled file. (See Note
4)
004
NUMERIC ID SET
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts and allows to set or
change the Numeric ID.
005
Not Used
006
ID DISPLAY
1 = Number (Numeric ID)
2 = Chara (Character ID)
3 = Name (Station Name)
4 = Dial (Dialing Number)
Selects the priority of displaying/Printing the ID, Name or Dialing
Number. (Default : 3 = Name)
1 = Number:Number>Name>Chara>Dial
2 = Chara
: Chara>Name>Number>Dial
3 = Name
: Name>Chara>Number>Dial
4 = Dial
: Dial>Name>Chara>Number
007
Not Used
008
MONITOR
1 = Off
2 = On
Selects whether the Monitor is ON/OFF for monitoring fax sig-
nals.
(FOR SERVICE USE ONLY)
009
DC LOOP
1 = Off (Normal)
2 = On (Off Hook)
Selects a false Off Hook state for back to back communication
test.
010
TX LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the TX signal output level, 0 to -15 dBm in 1 dBm steps.
(Refer to Chapter
Information Codes (INFO. CODES)
011
RX LEVEL
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
Selects the receiving sensitivity of -33/-38/-43/-48 dBm.
012
DTMF LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1 dBm steps.
013
G3 RX EQL
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
Selects the cable equalizer for G3 reception mode, 0dB, 4dB,
8dB or 12dB.
014
G3 TX EQL
1 = 0 dB
2 = 4 dB
3 = 8 dB
4 = 12 dB
Selects the cable equalizer for G3 transmission mode, 0dB, 4dB,
8dB or 12dB.
015
~
016
Not Used
Summary of Contents for UF-4500
Page 180: ...180 UF 5500 4500 ...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart ...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart ...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30 ...