10.1.9. Service Mode 9 (System Maintenance)
10.1.9.1. Overview
This Service Mode is used to maintain or update the firmware of the machine. Use the following
procedure for System Maintenance.
Note:
Now the machine is ready to accept programming firmware code from the PC.
1. Connect the machine to the PC with the USB Cable.
2. Start the Firmware Update Tool using the Wizard.
3. The firmware is copied into the machine.
4.
After the update is completed, the machine reboots itself and returns to standby.
System Maintenance Table
Service Mode 9
Step
Operation or Unit Condition
LCD Display
(The pictured model is UF-5500.)
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Enter the key operator password (The factory default ID is 00000000.) and press
"Set".
5
Press “9”.
6
Press “START”.
7
Press “SET”.
No.
Maintenance Mode
Description
1
FIRMWARE UPDATE
PC
-->
Host
Updates the firmware in the machine with the Master Firmware from the PC.
After the
firmware is updated, the machine reboots automatically and returns to standby.
8
SEND RECEIVED FILE
Transfers documents from memory to another fax machine during a fatal printer error.
Summary of Contents for UF-4500
Page 180: ...180 UF 5500 4500 ...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart ...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart ...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30 ...
Page 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1 ...
Page 297: ...297 UF 5500 4500 ...
Page 305: ...305 UF 5500 4500 ...
Page 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52 ...
Page 362: ...362 UF 5500 4500 ...