159
UF-5500 / 4500
421
RCV
B
Busy Tone is detected after sending NSF
Signal.
Remote station disconnected the line.
Wrong number is dialed.
422
XMT
B
Content of NSF (or DIS) or NSC (or DTC)
was invalid.
There is an incompatibility.
427
G3
RCV
B
DCN received to NSF/CSI/DIS transmitted. The interface is incompatible.
434
XMT or RCV
B
CD (response from Modem) did not turn
OFF within 180 sec. after receiver detected
FLAG signal.
Remote unit is defective.
MAIN PCB is defective.
436
G3 RX
C
DCN received after transmitting FTT.
Transmitter is defective or incompatible.
Line quality is poor.
456
RCV
B
Received relay transfer request or confi-
dential document to distribute to an end
receiving station or all confidential mail-
boxes are used.
490
RCV
C
Sum of error lines exceeded the limit (Func-
tion Parameter No. 70) of 64 lines.
Line quality is poor.
MAIN PCB is defective.
494
RCV
C
Interval between two EOLs was more than
10 sec. when receiver received message
data.
Transmitter is defective.
Line quality is poor. (EOL is damaged due to line
noise)
MAIN PCB is defective.
495
XMT
RCV
C
During reception, CD turned OFF or contin-
ued ON for long time. During communica-
tion, lost loop - current.
Line is disconnected.
Transmitter is defective.
MAIN PCB is defective.
501
XMT/
RCV(V.34)
B
Remote unit does not have compatible
Modem.
502
XMT/
RCV(V.34)
B, C, D
During reception, CD turned OFF or contin-
ued ON for long time. During communica-
tion, lost loop - current.
Line is disconnected.
Transmitter is defective.
MAIN PCB is defective.
503
XMT/
RCV(V.34)
B, C, D
CS of modem is not able to turn ON during
training.
MAIN PCB is defective.
Line is disconnected.
504
XMT/V.34
(Polling)
B
Polling is rejected from the remote station.
No polling original is set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling original is set.
540
XMT ECM
B
No response after transmitting 3rd CTC or
DCN received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd EOR or
received DCN.
Line is faulty.
MAIN PCB is abnormal.
542
XMT ECM
D
No response to the 3rd RR transmitted or
received DCN.
Remote unit is abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without MCF.
Remote unit is abnormal.
544
XMT ECM
D
Stopped Transmission after EOR Transmis-
sion.
Line is faulty.
MAIN PCB is abnormal.
550
RCV ECM
C
Timer between frames in phase C has
elapsed.
Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving EOR.
Line is faulty.
580
XMT
B
Sub-address transmission to a unit that has
their DIS bit 49 (NSF bit 155) OFF.
Sub-address transmission to a unit that has no
Sub-address function.
623
XMT
A
No original was in the ADF. (Built-in dialer
engaged)
Operator removed the original from the ADF
after dialing was completed.
Original was not set properly in the ADF.
630
XMT or RCV
(Polling)
B
Redial count over.
No dial tone detected. Sensor dial tone is not
detected. (destination dependent) Busy tone is
detected. (destination dependent) T1 timer (35
±
5 sec.) elapsed without a signal from the
receiver.
631
XMT
A
"STOP" button was pressed during Auto
Dialing.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Summary of Contents for UF-4500
Page 180: ...180 UF 5500 4500 ...
Page 248: ...248 UF 5500 4500 13 5 Test Chart 13 5 1 ITU T No 1 Test Chart ...
Page 249: ...249 UF 5500 4500 13 5 2 ITU T No 2 Test Chart ...
Page 281: ...281 UF 5500 4500 10 10 11 15 12 17 18 19 20 21 22 23 24 28 29 30 27 25 26 21 13 14 16 30 ...
Page 287: ...287 UF 5500 4500 130 131 132 133 134 135 136 137 138 139 140 141 PCB2 A UF 5500 only CN1 ...
Page 297: ...297 UF 5500 4500 ...
Page 305: ...305 UF 5500 4500 ...
Page 311: ...311 UF 5500 4500 501 502 503 504 506 507 505 508 509 511 510 514 513 512 P51 P53 P54 A51 P52 ...
Page 362: ...362 UF 5500 4500 ...