155
UF-5500 / 4500
11.2.7.2. Dialing Problems
11.2.7.3. Transmission Problems
START
END
No
Yes
Does the unit proceed to
Phase B?
1. Set documents on the ADF correctly.
4. Refer to Sect. 4.6.
3. The called party is busy.
2. Check the telephone line connection.
Are you using One-Touch,
ABBR or Phone Book
dialing?
Are you using direct dialing?
No
Yes
Check the registered telephone number.
Is the Monitor Volume
too loud or too low?
No
Yes
Check the dialed telephone number.
No
Yes
Adjust the monitor volume by pressing the
SET button and < or > arrows on the LCD.
START
END
Yes
No
Does the ID display?
1. No ID function at the remote unit.
2. The ID is not set for the remote unit.
Is the copy quality OK?
No
Any other problems?
Yes
No
Make a copy, and refer to Sect. 4.4.
Yes
See Sect. 4.3. (Troubleshooting with the
Information Codes).