CROSS REFERENCE:
11.3.11. Information Codes: 403, 411, 414, 415 (Polling Operator Trouble)
403,411,414
START
END
END
Review the polling operation
referring to the Operating
Instructions.
Yes
Yes
No
Does the remote side have
polling transmission
capability?
No
Ask the remote side to set
their unit for polling operation.
Is the remote side set to
polling transmission
(Polled) Mode?
Check the password
between the two units to
ensure it matches.
415
START
END
Inform the remote side
(receiving side) that their
machine does not have
polling transmission
capability.
Polling communication with 4-digit password is not an ITU-T Standard feature.
If the transmitter and receiver are of different manufacturers, polling communication
with password