1-34
1
1
Indoor unit
(B ) Pow er supply
Time delay fuse or
circuit capacity
2. 5 mm
2
E3
E1
S- 180PE3R 5
S- 200PE3R 5
S- 224PE3R 5
S- 160PE1R 5A
Max. 30 m
10- 16 A
Max. 130 m
10- 16 A
1-10. EL EC TR IC A L W
IR IN G
G eneral Precautions on W
iring
(1)
(4)
(5)
(6)
(7)
(8)
B ef ore w iring, conf irm the rated vo ltage of the unit as show n on its nameplate, then carry out the w iring closely f ollow ing
the w iring diagram.
(2)
(3)
This eq uipment is strongly recommended to b e installed w ith Earth Leaka ge Circuit B reake r (ELCB ) or R esidual Current
D evi ce (R CD ). O therw ise, it may cause electrical shock and f ire in case of eq uipment b reakd ow n or insulation b reakd ow n.
Earth Leaka ge Circuit B reake r (ELCB ) must b e incorporated in the f ixed w iring in accordance w ith the w iring regulations.
The Earth Leaka ge Circuit B reake r (ELCB ) must b e an approve d 10- 16 A, havi ng a contact separation in all poles.
To preve nt possib le haza rds f rom insulation f ailure, the unit must b e grounded.
Each w iring connection must b e done in accordance w ith the w iring syst em diagram.
W
rong w iring may cause the unit to misoperate or b ecome damaged.
D o not allow w iring to touch the ref rigerant tub ing, compressor, or any movi ng parts of the f an.
U nauthorize d changes in the internal w iring can b e ve ry dangerous. The manuf acturer w ill accept no responsib ility f or any
damage or misoperation that occurs as a result of such unauthorize d changes.
R egulations on w ire diameters dif f er f rom locality to locality. F or f ield w iring rules, please ref er to yo ur LO CAL ELECTR ICAL
CO D ES b ef ore b eginning.
Y ou must ensure that installation complies w ith all releva nt rules and regulations.
To preve nt malf unction of the air conditioner caused b y electrical noise, care must b e take n w hen w iring as f ollow s:
The remote control w iring and the inter- unit control w iring should b e w ired apart f rom the inter- unit pow er w iring.
U se shielded w ires f or inter- unit control w iring b etw een units and ground the shield on b oth sides.
(9) If the pow er supply cord of this appliance is damaged, it must b e replaced b y a repair shop designated b y the manuf acturer,
b ecause special- purpose tools are req uired.
R ecommended W
ire L ength and W
ire D iameter for Pow er S upply S ystem
C ontrol w iring
(C ) Inter-unit control w iring
(b etw een outdoor and indoor units)
(D ) R emote control w iring
0. 75 mm
2
(AW
G # 18)
0. 75 mm
2
(AW
G # 18)
U se sh ielded w iring*
1
Max. 500 m
Max. 1, 000 m
N O TE
* 1 W
ith ring- typ e w ire terminal.
W
A R N IN G
SM830262-00_大洋州向け シングル天埋_TD&SM.indb 34
18/01/26 13:2 :26
Summary of Contents for S-160PE1R5A
Page 8: ...vii MEMO SM830262 00_大洋州向け シングル天埋_TD SM indb 8 18 01 12 18 47 0 ...
Page 98: ...1 90 MEMO SM830262 00_大洋州向け シングル天埋_TD SM indb 0 18 01 26 13 2 4 ...
Page 196: ... MEMO 7 16 SM830262 00_大洋州向け シングル天埋_TD SM indb 16 18 01 2 17 42 12 ...
Page 218: ...201801 SM830262 00_大洋州向け シングル天埋_TD SM indb 1 17 12 27 14 22 33 ...