1-21
1
1
60B6LQJOHB%LJ3$&LQGE
1
2
3
4
5
6
7
8
Unit: mm
Mounting hole (4-R6.5),
anchor bolt : M10
Refrigerant tubing (liquid tube),
flared connection (ø9.52)
Refrigerant tubing (gas tube),
flared connection (ø19.05)
Refrigerant tubing port
Electrical wiring port (ø13)
Electrical wiring port (ø22)
Electrical wiring port (ø27)
Electrical wiring port (ø35)
29
1500
980
35
60
30
36
82
48
39
121
469
Z VIEW
370
60
60
89
35
82
48
39
121
4
5
6
7
8
5
6
7
8
4
A VIEW
62.5
50
47.5
75.5
16
13
20
412.5
350
160
200
230
160
660
160
(10)
170
370
36
980
4×
ȭ
32 holes (holes for drain)
330
1
A
Air-discharge
Air intake
Air intake
7
5
6
4
8
Z VIEW
42
74
100
120
173
16
51
35
47
Air-discharge
Air intake
When using a drain pipe, install the drain socket
(field supply) onto the drain port. Seal the other
drain port with the rubber cap.
43
2
3
Air intake
(B) Outdoor Unit: U-160PE2R8A, U-180PE2R8A
Specifi cation for pipe connecting indoor unit to outdoor unit.
Model name
Piping
Connections
2
5
.
9
ø
e
d
i
s
d
i
u
q
i
L
5
0
.
9
1
ø
e
d
i
s
s
a
G
U-160PE2R8A/
U-180PE2R8A
1-19
60B6LQJOHB%LJ3$&LQGE
1
2
3
4
5
6
7
8
Unit: mm
Mounting hole (4-R6.5),
anchor bolt : M10
Refrigerant tubing (liquid tube),
flared connection (ø12.7)
Refrigerant tubing (gas tube),
flared connection (ø19.05)*
1
Refrigerant tubing port
Electrical wiring port (ø13)
Electrical wiring port (ø22)
Electrical wiring port (ø27)
Electrical wiring port (ø35)
29
1500
980
35
60
30
36
82
48
39
121
469
Z VIEW
370
60
60
89
35
82
48
39
121
4
5
6
7
8
5
6
7
8
4
A VIEW
62.5
50
47.5
75.5
16
13
20
412.5
350
160
200
230
160
660
160
(10)
170
370
36
980
4×
ȭ
32 holes (holes for drain)
330
1
A
Air-discharge
Air intake
7
5
6
4
8
Z VIEW
42
74
100
120
173
16
51
35
47
Air-discharge
Air intake
When using a drain pipe, install the drain socket
(field supply) onto the drain port. Seal the other
drain port with the rubber cap.
Air intake
Air intake
(Gas piping connection) While the main gas side pipe is ø25.4,
since connecting the outdoor unit's 3-way valve requires a ø19.05
flare, please be sure to use standard accessories joint piping B or
A for connection (brazing), and connect as follows.
*
1
Specifi cation for pipe connecting indoor unit to outdoor unit.
A
8
R
2
E
P
4
2
2
/
A
8
R
2
E
P
0
0
2
-
U
Model name
Piping
Connections
7
.
2
1
ø
e
d
i
s
d
i
u
q
i
L
e
d
i
s
s
a
G
ø19.05 (~30m)
ø25.4 (30~50m)
(B) Outdoor Unit: U-200PE2R8A, U-224PE2R8A
2
3
12
SM830262-00_大洋州向け シングル天埋_TD&SM.indb 21
18/01/26 13:2 :23
Summary of Contents for S-160PE1R5A
Page 8: ...vii MEMO SM830262 00_大洋州向け シングル天埋_TD SM indb 8 18 01 12 18 47 0 ...
Page 98: ...1 90 MEMO SM830262 00_大洋州向け シングル天埋_TD SM indb 0 18 01 26 13 2 4 ...
Page 196: ... MEMO 7 16 SM830262 00_大洋州向け シングル天埋_TD SM indb 16 18 01 2 17 42 12 ...
Page 218: ...201801 SM830262 00_大洋州向け シングル天埋_TD SM indb 1 17 12 27 14 22 33 ...