Chapter 7
Appendix — Technical information
ENGLISH - 281
Data section
Blank
Mode
Blank
Random number section
Termination
symbol
Command
example
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘1’
0x31
‘ ’
0x20
“zzzzzzzz”
(ASCII code hex number)
(CR)
0x0d
Data length
9 bytes
1 byte
1 byte
1 byte
8 bytes
1 byte
f
Mode: 1 = Protect mode
f
Example: Response during protect mode (random number section is undefined value)
“NTCONTROL 1 23181e1e” (CR)
3) Generate a 32-byte hash value from the following data using MD5 algorithm.
f
“xxxxxx:yyyyy:zzzzzzzz”
xxxxxx
The user name for the administrator account
yyyyy
The password for the administrator account
zzzzzzzz
8-byte random number obtained in Step
2)
Command transmission method
Transmit using the following command formats.
r
Transmitted data
Header
Data section
Termination
symbol
Command
example
Hash value
“Connecting” (
x
page 280)
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
32 bytes
1 byte
1 byte
Undefined length
1 byte
f
Example: Transmission of power supply status acquisition command (hash value is calculated from the user
name and password of the administrator account, and acquired random number)
“dbdd2dabd3d4d68c5dd970ec0c29fa6400QPW” (CR)
r
Received data
Header
Data section
Termination
symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
1 byte
1 byte
Undefined length
1 byte
f
Example: The projector is powered on
“00001” (CR)
r
Error response
String
Details
Termination
symbol
Message
“ERR1”
Undefined control command
(CR)
0x0d
“ERR2”
Out of parameter range
“ERR3”
Busy state or no-acceptable period
“ERR4”
Timeout or no-acceptable period
“ERR5”
Wrong data length
“ERRA”
Password mismatch
Data length
4 bytes
―
1 byte
Note
f
The projector will automatically disconnect the connection with the network right after sending the command. This is the specification based
on the security view point to prevent unauthorized operation of this product by a malicious third party. To send commands continuously,
execute the network connection request every time the command is to be sent. For details, refer to “Communication flow between server
and client” (
x
page 283).