Chapter 4
Settings — [PROJECTOR SETUP] menu
ENGLISH - 169
[QUICK STARTUP]
Set if the [QUICK STARTUP] function is enabled or disabled.
1) Press
as
to select [QUICK STARTUP].
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Disables the [QUICK STARTUP] function.
[ON]
Enables the [QUICK STARTUP] function until the specified time set in [VALID PERIOD] elapses after
the projector enters the standby mode. The time until the projection starts after the power is turned on
will be reduced during the period when the [QUICK STARTUP] function is valid.
f
Proceed to Step
3)
when [ON] is selected.
3) Press the <ENTER> button.
f
The
[QUICK STARTUP]
screen is displayed.
4) Press
qw
to switch [VALID PERIOD].
f
The items will switch each time you press the button.
[30MIN.]
Sets the time until the [QUICK STARTUP] function is disabled after the projector enters the standby
mode.
Select a desired valid period.
[60MIN.]
[90MIN.]
Note
f
[QUICK STARTUP] cannot be set when [STANDBY MODE] is set to [ECO].
f
When [QUICK STARTUP] is set to [ON], the power consumption during standby becomes high during the period when the [QUICK
STARTUP] function is valid.
f
When [QUICK STARTUP] is set to [ON], the [QUICK STARTUP] function is disabled when the time set in [VALID PERIOD] elapses after the
projector enters the standby mode. The startup time and power consumption will be the same as when [QUICK STARTUP] is set to [OFF].
f
When [QUICK STARTUP] is set to [ON], the power indicator <ON (G)/STANDBY (R)> blinks red while in the standby mode during the period
when the [QUICK STARTUP] function is valid. The power indicator <ON (G)/STANDBY (R)> lights up red when the specified time set in
[VALID PERIOD] elapses after the projector enters the standby mode.
f
When [QUICK STARTUP] is set to [ON], the period when the [QUICK STARTUP] function is valid is counted as the projector runtime.
[POWER MANAGEMENT]
Set the function to save power consumption when there is no input signal.
[NO SIGNAL LIGHTS-OUT]
This is a function to automatically turn off the light source of the projector when there is no input signal for specific
period. The time until the light source is turned off can be set.
1) Press
as
to select [POWER MANAGEMENT].
2) Press the <ENTER> button.
f
The
[POWER MANAGEMENT]
screen is displayed.
3) Press
as
to select [NO SIGNAL LIGHTS-OUT].
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[DISABLE]
Disables the no signal lights-out function.
[10SEC.] - [5MIN.]
Turns off the light source when there is no input signal for the preset period.
Select [10SEC.], [20SEC.], [30SEC.], [1MIN.], [2MIN.], [3MIN.], or [5MIN.].
Note
f
The [NO SIGNAL LIGHTS-OUT] setting item is common with the following menu item.
g
The [PROJECTOR SETUP] menu
→
[NO SIGNAL SETTING]
→
[NO SIGNAL LIGHTS-OUT]
f
The fan will rotate to cool the projector while the no signal lights‑out function is operating and the light source is turned off. Also, the power
indicator <ON (G)/STANDBY (R)> blink green slowly.
f
When [NO SIGNAL LIGHTS-OUT] is set to anything other than [DISABLE], the following are the conditions to turn the light source back on
again from the condition that the light source has turned off by this function.