Chapter 4
Settings — [PROJECTOR SETUP] menu
ENGLISH - 163
f
Proceed to Step
9)
when [OFF] is selected.
f
Proceed to Step
11)
when [PC] is selected.
7) Press
as
to select [LINK].
8) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Performs automatic correction by this projector alone without synchronizing with other projectors.
The duration that the constant brightness is kept will become longer by setting the value of [LIGHT
OUTPUT] smaller.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Performs automatic correction by synchronizing multiple projectors.
Up to four groups (A to D) can be set within the same subnet by using the network function.
You can register and synchronize up to eight projectors in one group.
f
Proceed to Step
11)
when [AUTO] is selected in Step
6)
.
9) Press
as
to select [STARTUP CALIBRATION].
10) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Does not measure the brightness and color of the light source when the power is turned on.
[ON]
Measures the brightness and color of the light source by the brightness sensor after the power is
turned on and the light source is illuminated.
11) Press
as
to select [REGULAR CALIBRATION].
12) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Does not measure the brightness and color of the light source periodically.
[ON]
Measures the brightness and color of the light source by the brightness sensor at the time specified
by [CALIBRATION TIME].
f
Proceed to Step
17)
when [OFF] is selected.
13) Press
as
to select [CALIBRATION TIME].
14) Press the <ENTER> button.
f
The projector is in the adjustment mode (the time is blinking).
15) Press
qw
to select “hour” or “minute”, and press
as
or the number (<0> - <9>) buttons to set a
time.
f
Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows
setting of only the minute in increments of one minute between 00 and 59.
16) Press the <ENTER> button.
f
[CALIBRATION TIME] is set.
17) Press
as
to select [CALIBRATION MESSAGE].
18) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[ON]
Displays the time to complete the measurement while the brightness and color of the light source are
measured by the brightness sensor.
[OFF]
Does not display a message during the measurement.
19) Press
as
to select [APPLY].