<LAMP> and <TEMP> indicators
96 - ENGLISH
Maintenance
▶
■
Temperature indicator <TEMP>
Indicator
status
z
Illuminates red during projection.
(The message [REFER TO THE “TEMP indicator” SECTION IN THE OPERATION MANUAL.]
is displayed on the projection screen.)
z
Flashing red when the power is turned off (projection stops automatically).
Problem
The temperature inside and/or outside the projector is abnormally high.
Cause
z
Is the ventilating
port (intake/exhaust)
blocked?
z
Is the room
temperature too
high?
z
Is the air filter unit
clogged?
z
Is the projector used
at high elevations
1 400 m (4 593 ft) or
higher sea level?
Solution
z
Remove any objects
that are blocking
the ventilating port
(intake/exhaust).
z
Place the projector
in an environment
with temperature
and humidity as
designated in the
specifications.
(
page 117)
z
Clean or replace
the air filter unit.
(
page 97)
z
The projector can
only be used for two
minutes after turning
on the power. Set
[HIGH ALTITUDE
MODE] (
page 65)
to [ON] within two
minutes of turning
on the power.
Note
z
If the temperature indicator <TEMP> is still illuminating or flashing after taking the preceding measures, ask
your dealer to repair the unit.