2.8
System Option
System
93
Parameter
33. FWD / DND lamp pattern
Default
FWD: Flash, DND: On
Value Range
1.
FWD: Flash, DND: On
2.
FWD: On, DND: Flash
Description/Function
Specifies the lamp patterns of the FWD / DND button.
Reference
• 1.8 Ringing Features (F/G)
– Do Not Disturb (DND)
• 1.11 Transferring Features (F/G)
– Call Forwarding
Parameter
34. ELCOT / LCOT Busy-out Loop Relay
Default
OFF
Value Range
1.
ON
2.
OFF
Description/Function
When a CO line is busied out manually by the Manager / an
Operator, the state of Loop Relay is controled by this setting.
Note
•
In some countries, the ELCOT card must not be connected to the
Public Switched Network.
Reference
• 1.3 System Features (F/G)
– Trunk Busy-out
Parameter
36. Tone Mode
Default
Type-1: [SP], [NL], [G], Type-7: [JT]
Value Range
1.
Type-1
2.
Type-2
3.
Type-3
4.
Type-4
5.
Type-5
6.
Type-6
7.
Type-7
Description/Function
Specifies the Tone output type.
Note
•
The change of this parameter is activated after resetting the
system.
Reference
None
Summary of Contents for KX-TD500CE
Page 5: ...Configuration 5 Section 1 Configuration...
Page 30: ...1 9 PRI Port Assignment 30 Configuration...
Page 31: ...System 31 Section 2 System...
Page 32: ...2 1 System 32 System 2 1 System Used to assign parameters which affect system wide operation...
Page 100: ...2 9 Language Data 100 System...
Page 101: ...Group 101 Section 3 Group...
Page 102: ...3 1 Group 102 Group 3 1 Group Used to assign various group parameters...
Page 131: ...Line 131 Section 4 Line...
Page 183: ...Features 183 Section 5 Features...
Page 184: ...5 1 Features 184 Features 5 1 Features Used to assign parameters for various system features...
Page 218: ...5 15 Hotel 218 Features...
Page 219: ...Toll Restriction 219 Section 6 Toll Restriction...
Page 225: ...ARS Automatic Route Selection 225 Section 7 ARS Automatic Route Selection...
Page 234: ...7 5 Digits Modification Table 234 ARS Automatic Route Selection...
Page 235: ...Private Network 235 Section 8 Private Network...
Page 239: ...DDI DID 239 Section 9 DDI DID...
Page 246: ...9 2 Number Transformation 246 DDI DID...
Page 247: ...Maintenance 247 Section 10 Maintenance...
Page 268: ...10 7 System Time 268 Maintenance...
Page 269: ...Programming Error Messages 269 Section 11 Programming Error Messages...
Page 284: ...11 3 Information Message IXXXX 284 Programming Error Messages...
Page 285: ...Default Values 285 Section 12 Default Values...
Page 313: ...Default Values 313...