![Panasonic KX-TD500CE Programming Manual Download Page 271](http://html1.mh-extra.com/html/panasonic/kx-td500ce/kx-td500ce_programming-manual_4053274271.webp)
11.1
Error Messages (EXXXX)
Programming Error Messages
271
E0012
Another maintenance device is connected.
There are three ways to access the PBX: (1) By PC System Programming, (2) by
Remote System Programming, or (3) by User Programming. But only one at a time.
E0013
Please reconnect after the PBX becomes on-line or off-line completely.
Tried to connect the PC before the PBX became on-line or off-line completely.
Please try after the off-line indicator (on the top shelf) goes off (on-line) or turns on and
off (off-line).
E0014
Please enter profile name.
Attempted to save remote connection parameters without profile name.
E0015
Failed: Saving of remote connection parameters.
Remote connection parameters are saved as a file ("TD500.INI") in the Windows
system directory. The TD500 maintenance programme creates this file automatically if
the file does not exist. However, if the file exists and it is damaged, you will get this
error message. You must either repair the damage (using a text editor) or rename it as
a different file.
E0016
Failed: Deletion of remote connection parameters.
Deletion of remote connection parameters failed because file "TD500.INI" is damaged.
Please refer to the description of E0015.
E0017
Failed: Reading of remote connection parameters.
Reading of remote connection parameters failed because file "TD500.INI" is damaged.
Please refer to the description of E0015.
E0018
There is not enough space on your hard disk (or floppy) to save the system data.
Download is incomplete because there is not enough space on your hard disk (or
floppy) to save the system data.
E1001
You have exceeded the shelf limit of PT ports.
There is a limit of 128 PT ports per shelf when using DLC and DHLC cards. Please de-
assign one card and try again.
E1002
You have exceeded the system limit of trunk ports.
There is a limit of 192 trunk ports per system when using ELCOT, E1, E&M, BRI and
PRI30 cards. Please de-assign one card and try again.
E1003
You have exceeded the system limit of extension ports.
There is a limit of 448 extension ports per system when using DLC, DHLC, and ESLC
cards. Please de-assign one card and try again.
E1004
You have exceeded the system limit of trunk + extension ports.
There is a limit of 512 trunk + extension ports per system, using trunk and extension
cards. Please de-assign one card and try again.
E1005
You have exceeded the system limit of DISA cards.
There is a limit of 8 DISA cards per system.
Error Code
Error Message
Description
Summary of Contents for KX-TD500CE
Page 5: ...Configuration 5 Section 1 Configuration...
Page 30: ...1 9 PRI Port Assignment 30 Configuration...
Page 31: ...System 31 Section 2 System...
Page 32: ...2 1 System 32 System 2 1 System Used to assign parameters which affect system wide operation...
Page 100: ...2 9 Language Data 100 System...
Page 101: ...Group 101 Section 3 Group...
Page 102: ...3 1 Group 102 Group 3 1 Group Used to assign various group parameters...
Page 131: ...Line 131 Section 4 Line...
Page 183: ...Features 183 Section 5 Features...
Page 184: ...5 1 Features 184 Features 5 1 Features Used to assign parameters for various system features...
Page 218: ...5 15 Hotel 218 Features...
Page 219: ...Toll Restriction 219 Section 6 Toll Restriction...
Page 225: ...ARS Automatic Route Selection 225 Section 7 ARS Automatic Route Selection...
Page 234: ...7 5 Digits Modification Table 234 ARS Automatic Route Selection...
Page 235: ...Private Network 235 Section 8 Private Network...
Page 239: ...DDI DID 239 Section 9 DDI DID...
Page 246: ...9 2 Number Transformation 246 DDI DID...
Page 247: ...Maintenance 247 Section 10 Maintenance...
Page 268: ...10 7 System Time 268 Maintenance...
Page 269: ...Programming Error Messages 269 Section 11 Programming Error Messages...
Page 284: ...11 3 Information Message IXXXX 284 Programming Error Messages...
Page 285: ...Default Values 285 Section 12 Default Values...
Page 313: ...Default Values 313...