5.4 Programming the PBX
5.4.1 Easy Setup Wizard
In the Easy Setup Wizard, you will set up the mandatory settings required for the PBX.
When you log in to Web Maintenance Console for a PBX that is in its initialised, factory default state, the Easy
Setup Wizard for that PBX will launch automatically. You must log in using the Installer level account name
and password.
–
The Installer level account name is "INSTALLER".
–
The default Installer level account password is "1234".
1.
After Easy Setup Wizard launches, the
Easy Setup Wizard
screen appears:
a.
In
WebMC Language Setting
, select a language from the drop-down list.
b.
In
PBX Type
, select a PBX type.
Standalone
:
This PBX will be used as a standalone system. The standalone PBX controls all terminals, trunks, and
applications.
Slave
:
This PBX will serve as a Slave unit in a One-look network. The Slave unit can share setup information
and resources controlled by the Master unit.
Note
When
Slave
is selected, the
Location Setting
and
Password
settings are not editable. Skip these
settings and go to
One-look Network
(step
e
).
c.
In
Location Setting
, select a location from drop-down list.
d.
In
Password Setting
, enter a password for the Installer level account. In
Re-enter
, enter the same
password.
Note
•
The installer password must be changed from its default setting.
e.
When
Slave
is selected in step
b
, in
One-look Network
, specify whether to activate the 60-day
One-look Networking Trial Activation Key.
–
If
Active
is selected, the 60-day trial will begin when the Easy Setup Wizard is completed.
–
If
Non Active
is selected, you will have to activate the trial manually in order to use One-look
Networking Features on a trial basis.
f.
Click
Start Setup Wizard
.
Note
If the location is changed from its default value, a notice about restarting the PBX is displayed. Click
OK
to restart the PBX. After the PBX restarts, start Web Maintenance Console again (refer to
"Connecting to Web Maintenance Console" in "5.3 Starting Web Maintenance Console"). When you
start the Easy Setup Wizard again, you will start from step
1
, below.
2.
In the
Date & Time
Settings:
a.
Select a time zone from the drop-down list.
b.
Click the
Local Time
box, and then select the date and time from the menu.
c.
In
Automatic Time Adjustment
, enter information as necessary.
d.
In
Daylight Saving
, select the appropriate option.
e.
Click
Next
.
3.
In the
Numbering
settings:
a.
In
Feature No
, select the appropriate option.
b.
In
CO Access/Operator No
, select the appropriate options.
Installation Manual
197
5.4.1 Easy Setup Wizard
Summary of Contents for KX-NS500
Page 16: ...16 Installation Manual Table of Contents ...
Page 28: ...28 Installation Manual 1 4 Data Security ...
Page 58: ...58 Installation Manual 2 3 3 System Capacity ...
Page 78: ...78 Installation Manual 3 1 3 Using CTI Applications ...
Page 114: ...4 Hook the main unit on the screw heads 114 Installation Manual 4 2 10 Wall Mounting ...
Page 286: ...286 Installation Manual 6 1 Methods of Stacking Expansion Units ...
Page 300: ...300 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Page 332: ...332 Installation Manual 8 6 Port Security ...
Page 337: ...Installation Manual 337 Notes ...