the number of connected DPTs
–
the maximum number of DPTs the PBX can support
The table below shows examples of how many Digital XDP ports can be assigned with different configurations.
For details about the Digital XDP connection, refer to "4.8.3 Digital EXtra Device Port (Digital XDP)
Connection".
KX-NS500 w/
o option
KX-NS500
max.
KX-NS500 w/
1 KX-NS520
KX-NS500 w/
2 KX-NS520
KX-NS500 w/
3 KX-NS520
No. of DPT ports
2
18
(16
´
1+2)
34
(16
´
2+2)
50
(16
´
3+2)
66
(16
´
4+2)
No. of Digital XDP
ports
2
16
32
48
64
Total No. of DPTs
4
32
(16+16)
64
96
128
Power Supply Unit Capacity
The pre-installed power supply unit (PSU) in each PBX supports a different load figure.
PBX Model
Maximum Load Figure
KX-NS500
40
KX-NS520
40
Load Figure Calculation
Equipment Type
Item
Load Figure
PT
DPT
1
DPT
(KX-T7400 series/
KX-T7500 series)
2
DSS Console
1
D-XDP
0.5
APT
1.5
IP-PT
0
SIP-EXT
0
CS
DPT I/F CS (2ch)
2
DPT I/F CS (8ch)
8
SLT
DHLC4
4
SLC8
8
SLC16
16
KX-NS500
(Preinstalled SLC)
16
Installation Manual
53
2.3.3 System Capacity
Summary of Contents for KX-NS500
Page 16: ...16 Installation Manual Table of Contents ...
Page 28: ...28 Installation Manual 1 4 Data Security ...
Page 58: ...58 Installation Manual 2 3 3 System Capacity ...
Page 78: ...78 Installation Manual 3 1 3 Using CTI Applications ...
Page 114: ...4 Hook the main unit on the screw heads 114 Installation Manual 4 2 10 Wall Mounting ...
Page 286: ...286 Installation Manual 6 1 Methods of Stacking Expansion Units ...
Page 300: ...300 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Page 332: ...332 Installation Manual 8 6 Port Security ...
Page 337: ...Installation Manual 337 Notes ...