For the KX-UT series:
Application
LAN Side Port Number
WAN Side Port Number
SIP Proxy
UDP Port No. for SIP Extension
Server
(refer to PC Programming Manual
"9.2.2 PBX Configuration—[1-1]
Configuration—Slot—System
Property—Site—Port Number")
NAT-SIP Proxy Port No.
(Use the same value as
NAT - SIP
Proxy Server Port No.
"Programming the PBX with Built-in
Media Relay Gateway")
CWMP
HTTP
CWMP (HTTP) Port No. for
SIP-MLT
(Use the same value as in step
"Programming the PBX with Built-in
Media Relay Gateway".)
NAT - CWMP Server (HTTP) Port
No.
(Use the same value as in step
of
"Programming the PBX with Built-in
Media Relay Gateway".)
HTTPS
CWMP (HTTPS) Port No. for
SIP-MLT
(Use the same value as in step
"Programming the PBX with Built-in
Media Relay Gateway".)
NAT - CWMP Server (HTTPS) Port
No.
(Use the same value as in step
of
"Programming the PBX with Built-in
Media Relay Gateway".)
SIP-MLT Data
HTTP
Data Transmission Protocol
(HTTP) Port No. for SIP-MLT
(Use the same value as in step
"Programming the PBX with Built-in
Media Relay Gateway".)
Data Transmission Protocol
(HTTP) Port No. for SIP-MLT
(Use the same value as in step
of
"Programming the PBX with Built-in
Media Relay Gateway".)
HTTPS
Data Transmission Protocol
(HTTPS) Port No. for SIP-MLT
(Use the same value as in step
"Programming the PBX with Built-in
Media Relay Gateway".)
NAT - SIP-MLT Data Download
Server (HTTPS) Port No.
(Use the same value as in step
of
"Programming the PBX with Built-in
Media Relay Gateway".)
NTP
NAT - NTP Server Port No.
(Use the same value as in step
of
"Programming the PBX with Built-in
Media Relay Gateway".)
RTP (UDP)
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS500 uses.)
Start/End RTP (UDP) Port No.
(Use port numbers that are in the
range of the RTP ports that the
KX-NS500 uses.)
Make sure the RTP Start Port (UDP) and the RTP End Port (UDP) specified
for the router are in the range of the RTP ports that the KX-NS500 uses. For
the range of RTP port numbers that the KX-NS500 uses, refer to "Port
Numbers for Optional DSP Card" in "8.6 Port Security".
*1
The port number for NTP that the KX-NS500 uses is fixed to 123.
*2
The port number ranges must be within the range of RTP/RTCP for NAT traversal (16000–18047).
Installation Manual
271
5.8.4 Installing IP Phones at a Remote Site with a Built-in Media Relay Gateway
Summary of Contents for KX-NS500
Page 16: ...16 Installation Manual Table of Contents ...
Page 28: ...28 Installation Manual 1 4 Data Security ...
Page 58: ...58 Installation Manual 2 3 3 System Capacity ...
Page 78: ...78 Installation Manual 3 1 3 Using CTI Applications ...
Page 114: ...4 Hook the main unit on the screw heads 114 Installation Manual 4 2 10 Wall Mounting ...
Page 286: ...286 Installation Manual 6 1 Methods of Stacking Expansion Units ...
Page 300: ...300 Installation Manual 7 1 6 Troubleshooting by Error Log ...
Page 332: ...332 Installation Manual 8 6 Port Security ...
Page 337: ...Installation Manual 337 Notes ...