5-47
Troubleshooting
E1-21: Mirror ratio drive
When the mirror stepping motor drives to the mirror home position sensor
and is not detected within a predetermined time.
Does the mirror unit move when the
NO
Mirror stepping motor connector is shorted or
power switch is turned ON?
broken.
YES
CN-115 or CN-123 (of LVPS PCB) is shorted or
broken.
Mirror drive mechanism is defective.
Mirror stepping motor is defective.
CPU PCB is defective.
Is DC5V (output signal) detected on the
NO
Is DC5V detected on the CN11-3 of the CPU
Mirror position sensor connector CN-1 ?
PCB?
YES
YES: Home position sensor connector is
shorted or broken.
NO:
Check all DC5V lines.
Does CN11-2 (output signal of CPU PCB)
NO
Home position sensor connector is shorted or
change when the home position sensor is turned
broken.
ON/OFF.
Home position sensor mounting position is
incorrect.
Home position sensor is defective.
YES
CPU PCB is defective.
E1-23: F8-02 mis-input
Measurement input for adjusting the
Input the average measurement correctly.
original registration
Adjust F8-01 and F8-02 again.
E1-32: Auto original density detection
When the auto original density signal is not detected, or the auto original density
can not be adjusted.
Is original density sensor dirty?
YES
Clean the original density sensor.
NO
Is DC10V signal detected on CN11-12 CPU
YES
Original density sensor connector is shorted or
PCB?
broken.
Original density sensor is defective.
NO
PCB is defective.
Summary of Contents for FP-7818
Page 8: ......
Page 236: ...27 Sheet Bypass Tray PM102 8 1 7 5 3 4 6 10 11 4 12 13 9 16 15 18 14 4 17 2...
Page 238: ...28 ADU PM801 16 8 1 4 14 12 10 11 11 13 13 6 7 8 16 9 5 3 2 15...
Page 360: ...1 4 7 10 8 9 5 6 2 3 1 Sorter Mounting Assembly...
Page 362: ...1 2 5 J41 3 6 7 8 4A 4 2 Covers...
Page 370: ...A 4 5 2 6 3 4 7 1 9 9 12 10 13 14 15 16 17 18 19 20 21 22 8 J22 M4 M2 J35 A 6 Drive Block...
Page 379: ...1 2 3 4 5 6 7 10 8 9 1 Sorter...
Page 381: ...1 A 3 4 5 12 13 15 9 10 11 6 7 8 16 2 14 13A J202 J202 J104 2 Covers...